Body control
module (A) receives various input switch signals controlling time
and alarm functions for tail lamp, rear fog lamp, tail lamp auto
cut, auto light, DRL, seat belt reminder warning, key operated
warning, parking brake warning, over speed warning, ignition key
hole illumination, room lamp control, power window delay time
control, keyless entry control, burgular alarm control, auto door
lock/crash door unlock, key reminder & front/rear heated
control.
|

|
| 1. |
WASHER INTERLOCKING WIPER
| (1) |
If the Washer SW is ON in the IGN2 SW ON
state, then the Wiper output shall be ON after T1, and if the
Washer SW input is ON for 0.2~0.6 seconds, then the Wiper
output shall be OFF after T3. However, WASHER SW input shall
be disregarded during the Washer Wiper operating, but after
operating the Washer Wiper, WASHER SW input shall be accepted
first.

T1 : 0.3 ± 0.1s, T2 : 0.2~0.6s, T3 : 0.7
± 0.1s.
In case of T2 is less than 0.2s,
T3=0 |
| (2) |
If the Washer SW is ON in the IGN2 SW ON
state, then the Wiper output shall be ON after T1, and if the
Washer SW is ON over 0.6 seconds, after the Washer SW is OFF
and the Wiper output shall be ON for 2.5~3.8 seconds and then,
the Wiper output shall be OFF. However, WASHER SW input shall
be disregarded during the Washer Wiper operating, but after
the Washer Wiper operating, WASHER SW input be accepted
first.

T1 : 0.3 ± 0.1s, T2 : more than 0.6s,
T3 :
2.5~3.8s. |
| (3) |
During INT Wiper operating, if the
Washer SW is ON over 0.6 seconds, then the Washer Interlocking
Wiper output shall be ON. If the Washer SW is ON for 0.2~0.6
seconds, then the Wiper output shall be ON once.

T1 : 0.3 ± 0.1s, T2 : more than
0.6s,
T3 : 2.5~3.8s ± 0.1s, T4 : INT
TIME-0.7s,
T5 : 0.2~0.6s, T6 : 0.7 ±
0.1s. | |
| 2. |
MIST INTERLOCKING WIPER
| (1) |
In IGN2 SW ON, if the MIST SW is ON for
60ms or more, within 100ms, and then, wiper output shall be ON
for 700ms within 100ms.

T1 : Min 60 ms, T2 : Max 100
ms,
T3 : 700 ± 100
ms. |
| (2) |
If MIST SW input is continued, WIPER
output shall be maintain the ON state, and then if MIST SW is
OFF, the Wiper output shall be ON for 700ms since OFF
time.

T1 : Min 60 ms, T2 : Max 100
ms,
T3 : 700 ± 100 ms, T4 : 700
ms |
| (3) |
Mist SW input shall be disregarded by
INT WIPER, WASHER interlocking WIPER during operating
WIPER. | |
| 3. |
INT WIPER
According to the vehicle speed, control
intermittent time of the Intermittent Wiper.
| C. |
INPUT the vehicle speed and the VOLUME
value for setting the intermittent
time |
| (1) |
Output of Intermittent time
ratio
Calculate the INT time rate by inputting
the INT Time set Volume value (input voltage)
"The INT Time Rate is to indicate the
position where the Volume is located from the Slow (100%) to
the Fast (0%) of the Knob. Therefore the Volume shall be
linearly calibrated about the input voltage"
Input
|
INT
Time
|
Voltage (V)
|
Ratio (%)
|
0
|
0
|
1.582
|
25
|
2.404
|
50
|
2.907
|
75
|
3.247
|
100
|
|
| (2) |
Output of Standard Intermittent
Time
"Calculate the intermittent time of the
intermittent time ratio 100%and 0% at the vehicle speed (V)
computed in (1) term by linear correction "
Int
Vol.
|
Int Time
(Min.)
|
Int Time
(Typ.)
|
Int Time
(Max.)
|
FAST (0%)
|
1.98
|
2.2
|
2.42
|
MID (25%)
|
3.51
|
3.9
|
4.29
|
MID (50%)
|
5.49
|
6.1
|
6.71
|
MID (75%)
|
7.47
|
8.3
|
9.13
|
SLOW (100%)
|
9
|
10
|
11
|
| |
| 4. |
CONTROL of REAR WASHER Interlocking REAR WIPER
| (1) |
If Rear Washer Switch is ON with IGN2
Switch ON, turn ON Rear Wiper Relay output after T1.
If Rear Washer SW Input is carried on
for 0.2~0.6 second, turn OFF Rear Wiper RLY after T3.
However, Rear Washer SW input generated
during operating Rear Wiper RLY is ignored, and received
following the operation of Rear Wiper RLY.

T1 : 0.3±0.1 s, T2 : 0.2~0.6s, T3 :
0.7±0.1s.
if T2 is net more than 0.2 Sec,
T3=0 |
| (2) |
If Rear Washer SW is ON with IGN2 switch
ON, turn ON Rear Wiper relay output after T1.
If Rear Washer switch input is continued
for more than 0.6, turn ON and OFF Rear Wiper relay Output for
2.5~3.8 seconds after turning Rear Washer switch OFF. However
Rear Washer switch Input during operating Rear Wiper relay is
ignored and received after the operation of Rear Wiper
relay

T1 : 0.3±0.1 s, T2 : More than 0.6s, T3
: 3s. |
| (3) |
Rear Washer SW Input is ignored during
continuous operation of Rear Wiper RLY generated by Rear Wiper
SW. |
| (4) |
The function of REAR WASHER interlocking
REAR WIPER is primarily taken, in case that Rear Washer switch
Input is generated during intermittent operation of Rear Wiper
relay by Rear Wiper
switch | |
| 5. |
TAIL LAMP AUTO CUT
After Key IN SW is On, if Tail SW is On, then
Key IN SW shall be OFF; when the driver's door is opened, then the
Tail Lamp shall be OFF automatically.
Also, in the state that the KEY IN SW is ON,
after the driver's door is opened, if the KEY IN SW is OFF, then the
Tail Lamp shall be OFF automatically.
After the Auto Cut, if the Tail SW is ON after
OFF again, the Tail Lamp shall be ON, and the Auto Cut function
shall be canceled.
After the Auto Cut, when KEY IN SW is ON
again, TAIL LAMP shall be ON, and the Auto Cut function shall be
canceled.
In the state of the AUTO CUT, if mounting or
removing the BATTERY, then the AUTO CUT state shall be
continued.

|
| 6. |
HEAD LAMP LOW CONTROL
If HEAD LAMP LOW SW is On in the IGN1 On
state, HEAD LAMP HIGH RELAY shall be ON so that HEAD LAMP HIGH can
be controlled by HEAD LAMP RELAY and M/F SW.

|
| 7. |
AUTO LIGHT CONTROL
| (1) |
It shall be able to operate only in case
of AUTO LIGHT is active, and comply with CALIBRATION PARAMETER
TABLE of each spec. |
| (2) |
IGN1 SW ON state, if the supply voltage
of the AUTO LIGHT SENSOR is less than 4v or more than 6v, it
is determined as the fault. In the fault state, in case of the
AUTO LIGHT SW is ON, always HEAD LAMP RELAY shall be ON
regardless of the Sensor value. FILTERING TIME for the fault
and recovery with regard to the supply voltage is 300 msec
respectively. |
| (3) |
In the condition of LIGHT ON, when the
AUTO LIGHT SENSOR value is entered into AUTO LIGHT control
condition, then LIGHT shall be ON
immediately. |
| (4) |
If IGN1 SW is ON, and AUTO LIGHT SW is
ON, and in LIGHT OFF state, and in case of AUTO LIGHT SENSOR
value is the input value of the LIGHT ON, LIGHT shall be ON
after 12 ± 0.2sec. |
| (5) |
In LIGHT ON state, in case of the AUTO
LIGHT SENSOR value is the input value of the LIGHT OFF, LIGHT
shall be OFF after 12 ±
0.2sec. |
| (6) |
If the SENSOR value is the input value
of the TAIL LAMP ON, then TAIL LAMP RELAY shall be ON only,
and if it is the input value of the HEAD LAMP ON, then HEAD
LAMP HIGH RELAY shall be ON so that HEAD LAMP HIGH can be
controlled by TAIL LAMP RELAY, HEAD LAMP RELAY, and
multifunction (M/F) SW. |
| (7) |
In the condition of LIGHT ON, when AUTO
LIGHT SW is ON, HEAD LAMP RELAY shall be ON immediately, and
when AUTO LIGHT SW is OFF, LIGHT shall be OFF
immediately.
The LIGHT ON value of the AUTO LIGHT
SENSOR shall be complied with the table below.
|
Tail
lamp
|
Head
lamp
|
ON
|
2.5 ± 0.05V
|
OFF
|
4.0 ±
0.05V
|

|
| (8) |
The time chart according to filtering
time and sensor for each applicable area shall be as
follow.

T1 : 12 ± 0.2s, T2 : 12 ±
0.2s. | |
| 8. |
Tail Interlocking av control
| (1) |
If AutoLight power is less than 4V or
over 6V with A_ACC ON, it is considered to be malfunctioning.
AV Tail Output should be OFF in
malfunctioning. Power supply FILTERING time of failing and
recovering takes 300msec each.
|
| (2) |
If AutoLight sensor value is equal to
the input value of TAIL LAMP ON with ACC ON, turn ON AV Tail
Output after 12 ± 0.2 sec. |
| (3) |
If AutoLight sensor value is equal to
the input value of TAIL LAMP OFF with AV Tail Output ON, turn
OFF AV Tail Output after 12 ±
0.2sec. |
| (4) |
A_AutoLight sensor value of LIGHT ON is
as follows.
|
AV tail
output
|
|
ON
|
2.5±0.05V
|
|
OFF
|
4.0±0.05V
|
|


T1 : 12 ± 0.2s, T2 : 12 ±
0.2s. | |
| 9. |
DAYTIME RUNNING LIGHT
DRL (DAYTIME RUNNING LIGHT) OPTION is
classified into the following two cases by the DRL OPTION LINE
input.
| (1) |
NON-DRL OPTION: In the case that DRL
OPTION LINE is not connected. |
| (2) |
DRL OPTION: In the case that DRL CANADA
OPTION LINE is connected and electrically
grounded. | |
| 10. |
DRL (CANADA)
If the IGN2 is ALT "L" are On, supply the
power to the HEAD LAMP HIGH LAMP by turning the DRL CANADA RELAY
ON.
If HEAD LAMP LOW RELAY is On by the HEAD LAMP
switch, the DRL function shall be canceled. If the HEAD LAMP HIGH
RELAY is On by the HEADLAMP HIGH switch or PASSING switch, the DRL
function shall be canceled.
If P/BRAKE switch is ON(PARK), the DRL
function shall be canceled.
In IGN2 state, if the HEAD LAMP HIGH RELAY is
On by the HEADLAMP HIGH switch or PASSING switch, the HEAD LAMP HIGH
INDICATOR shall be ON.

|
| 11. |
BUZZER SOUND
| (1) |
BUZZER SOUND SPECIFICATION
|
Frequency
|
Frequency DUTY
|
Cycle
|
Sound
Pressure
|
Remark
|
Seat Belt Warning
|
800Hz
|
50%
|
1.0s
|
70±10Db
|
Decremental Sound
|
Key Operated
|
800Hz
|
50%
|
0.7s
|
70±10Db
|
Decremental Sound
|
Parking Start Waring
|
800Hz
|
50%
|
1.0s
|
70±10Db
|
Continuous
Sound
|

|
| (2) |
The Priority Order : S/BELT WARNING >
KEY OPERATED WARNING > PARKING START
WARNING |
| (3) |
If the output is OFF, maintain the
output until the OFF cycle |
| (4) |
Sound pressure measurement distance :
1.0 m | |
| 12. |
SEAT BELT REMINDER
FROM STATE IGN1 ON DRIVER
UNBELTED
Condition 1
State
|
Description
|
Initial
condition
|
IGN1 ON
DRIVER UNBELTED
|
Event
|
IGN1
OFF
|
Action
|
| -
|
Stop Bulb check 6 seconds driver
indicator blinking |
| -
|
Stop Normal 6 seconds driver
indicator blinking |
| -
|
The automaton state is changed to
IGN1
OFF | |
Condition 2
State
|
Description
|
Initial
condition
|
IGN1 ON
DRIVER UNBELTED
|
Event
|
Driver
side seat belt is belted
|
Action
|
| -
|
Stop Normal 6 seconds driver
indicator blinking |
| -
|
Stop ALL 6 seconds buzzer
warning |
| -
|
The automaton state is changed to
IGN1 ON DRIVER
BELTED | |
Condition 3
State
|
Description
|
Initial
condition
|
IGN1 ON
DRIVER UNBELTED
|
Event
|
Vehicle
Speed >= 10km/h
|
Action
|
| -
|
Start buzzer and driver indicator
Pattern (10 times (6sec ON/24sec OFF) + 6sec
ON) |
| -
|
The automaton state is changed to
PATTERN | |
FROM STATE PATTERN
Condition 4
State
|
Description
|
Initial
condition
|
PATTERN
|
Event
|
IGN1
OFF
|
Action
|
| -
|
Stop Buzzer and driver indicator
Pattern |
| -
|
Stop ALL 6s driver indicator
blinking |
| -
|
Stop ALL 6s buzzer
warning |
| -
|
The automaton state is changed to
IGN1
OFF | |
Condition 5
State
|
Description
|
Initial
condition
|
PATTERN
|
Event
|
Driver
side seat belt is belted
|
Action
|
| -
|
Stop Buzzer and driver indicator
Pattern |
| -
|
Stop Normal 6s driver indicator
blinking |
| -
|
Stop ALL 6s buzzer
warning |
| -
|
The automaton state is changed to
IGN1 ON DRIVER
BELTED | |
Condition 6
State
|
Description
|
Initial
condition
|
PATTERN
|
Event
|
Vehicle
Speed <= 5km/h
|
Action
|
| -
|
Stop Buzzer and driver indicator
Pattern |
| -
|
if 6s buzzer period, after 6s
warning stop Pattern |
| -
|
The automaton state is changed to
IGN1 ON DRIVER
UNBELTED | |
|
| 13. |
KEY OPERATED WARNING
| (1) |
In state of KEY IN SW is IN, if the
DRIVER DOOR is opened, then the CHIME BUZZER output shall be
continued with the cycle of 0.7
seconds. |
| (2) |
If KEY IN SW is OUT or the driver's door
is closed during the Chime Buzzer output, then the output
shall be OFF.

T1 : 0.7 ±
0.1sec. | |
| 14. |
PARKING START WARNING
In the state that the IGN1 is ON or the
Parking Brake is pulled, if the speed of vehicle is maintained over
10 km/h for 2~3 seconds or more, then the Chime Buzzer output shall
be continued with 1 second cycle of the ON/OFF (0.3/0.7 seconds).
But, after the speed of vehicle is maintained over 10 km/h for 2~3
seconds or more, if the Parking Brake is pulled, output
immediately.

T1 : 2.5±0.5 sec, T2 : 0.3±0.1
sec,
T3 : 0.7±0.1
sec. |
| 15. |
IGN KEY HOLE ILLUMINATION
| (1) |
If the driver's door (or assist’s door)
is opened in the state that the IGN1 SW is OFF, then the IGN
Key Hole Illumination shall be
ON. |
| (2) |
In the (1) state, if the driver's door
(or assist's door) is closed, then the IGN Key Hole
Illumination shall be OFF after it is in the ON state for 30
seconds. |
| (3) |
During the (1) and (2) operating, if the
IGN1 SW is On, the IGN Key Hole Illumination shall be OFF
immediately. |
| (4) |
But, if it is in the ARM or ARM WAIT or
ALARM or REARM Mode, then the IGN Key Hole Illumination shall
be OFF immediately.

T1 : 30 ± 1
sec. | |
| 16. |
DEFOGGER TIMER
| (1) |
If the Defogger SW is ON after the ALT
"L" is ON in the state that the IGN1 SW is ON, then the
Defogger output shall be ON for 20 minutes. (Operating in the
state of the ENGINE RUNNING) |
| (2) |
If the DEFOGGER SW is ON again while the
DEFOGGER output is ON, then the DEFOGGER output shall be
OFF. |
| (3) |
If the ALT "L" is OFF or IGN1 is OFF
while the DEFOGGER output is ON, then the DEFOGGER output
shall be OFF. |
| (4) |
If the ALT "L" > 10 volts, then it
shall be in the Engine Running State (ALT "L" shall be ON); if
the ALT "L" < 5 volts, then it shall be in the Engine Stop
State (ALT "L" shall be OFF). Also, if the ALT "L" is more
than 5 and less than 10 volts, then the former state shall be
maintained. |
| (5) |
If the defogger SW is pressed and the
ALT "L" is ON, there shall be no the DEFOGGER RLY
output.

T1 : 60 ± 20 msec, T2 : 20 ± 1
min. | |
| 17. |
DECAY ROOM LAMP & KEYLESS UNLOCK
TIMER
Condition 1
State
|
Description
|
Initial
Condition
|
Room
lamp OFF & IGN1 OFF & 4DOOR AND Tailgate
CLOSE
|
Transition Condition
|
In the
state that all doors are closed, the 4DOOR or T/GATE is opened
over 0.1 seconds.
|
Operating
|
| -
|
Entry into the ROOM LAMP ON state
for 20 min |
| -
|
ROOM LAMP ON for 20 ± 1
min | |
Condition 2
State
|
Description
|
Initial
Condition
|
Room
lamp OFF & IGN1 OFF & 4DOOR AND Tailgate
CLOSE
|
Transition Condition
|
In case
of UNLOCK by the TX
|
Operating
|
| -
|
Entry into the ROOM LAMP ON state
for 30s |
| -
|
ROOM LAMP ON for 30 ±
3seconds | |
Condition 3
State
|
Description
|
Initial
Condition
|
Room
lamp OFF & IGN1 OFF & 4DOOR AND Tailgate
CLOSE
|
Transition Condition
|
IGN1 ON
and 4 DOOR or Tailgate OPEN over 0.1 seconds
|
Operating
|
| -
|
Entry into the ROOM LAMP ON
state |
|

T1 : 20 ± 1 min, T2 : 30 ± 3 sec,
T3 : 100 ms.
Condition 4
State
|
Description
|
Initial
Condition
|
ROOM
LAMP ON for 30s & IGN1 OFF
|
Transition Condition
|
In the
state that all doors are closed, the 4DOOR or Tailgate is
opened over 0.1 seconds.
|
Operating
|
| -
|
Entry into the ROOM LAMP ON state
for 20 min |
| -
|
ROOM LAMP ON for 20 ±
1min. | |
Condition 5
State
|
Description
|
Initial
Condition
|
ROOM
LAMP ON for 30s & IGN1 OFF
|
Transition Condition
|
In case
of UNLOCK by the TX.
|
Operating
|
| -
|
Maintain in the ROOM LAMP ON state
for 30s |
| -
|
Extend the ROOM LAMP ON state for
30
seconds. | |
Condition 6
State
|
Description
|
Initial
Condition
|
ROOM
LAMP ON for 30s & IGN1 OFF
|
Transition Condition
|
IGN1 ON,
or after 30 seconds, or when entered into the ARM state, or
when all doors are locked.
|
Operating
|
| -
|
Entry into the ROOM LAMP DECAYING
state |
| -
|
After the ROOM LAMP is decayed for
2 ± 0.2 seconds, it shall be
OFF. | |

T1 : 20 ± 1 min, T2 : 30 ± 3 sec,
T3 : 100 ms.
Condition 7
State
|
Description
|
Initial
Condition
|
ROOM
LAMP ON for 20min & IGN1 OFF
|
Transition Condition
|
IGN1
ON
|
Operating
|
| -
|
Entry into the ROOM LAMP ON
state |
|
Condition 8
State
|
Description
|
Initial
Condition
|
ROOM
LAMP ON for 20min & IGN1 OFF
|
Transition Condition
|
4DOOR
AND Tailgate CLOSE
|
Operating
|
| -
|
Entry into the ROOM LAMP ON state
for 30s. |
| -
|
ROOM LAMP ON for 30 ± 3
seconds. | |
Condition 9
State
|
Description
|
Initial
Condition
|
ROOM
LAMP ON for 20min & IGN1 OFF
|
Transition Condition
|
4DOOR
AND Tailgate CLOSE & When All doors are locked, or After
20 minutes
|
Operating
|
| -
|
Entry into the ROOM LAMP DECAYING
state |
| -
|
The ROOM LAMP is decayed for 2 ±
0.2 seconds and then, shall be
OFF. | |

T1 : 20 ± 1 min, T2 : 30 ± 3 sec,
T3 : 100 ms.
Condition 10
State
|
Description
|
Initial
Condition
|
ROOM
LAMP DECAY & IGN1 OFF
|
Transition Condition
|
In the
state that all doors are closed, 4DOOR or T/GATE OPEN over 0.1
seconds
|
Operating
|
| -
|
Entry into the ROOM LAMP ON state
for 20min |
| -
|
ROOM LAMP ON for 20 ±
1minutes. | |
Condition 11
State
|
Description
|
Initial
Condition
|
ROOM
LAMP DECAY & IGN1 OFF & 4DOOR AND Tailgate
CLOSE
|
Transition Condition
|
In case
of UNLOCK by the TX
|
Operating
|
| -
|
Entry into the ROOM LAMP ON state
for 30s |
| -
|
ROOM LAMP ON for 30 ± 3
seconds. | |
Condition 12
State
|
Description
|
Initial
Condition
|
ROOM
LAMP DECAY
|
Transition Condition
|
After
completing the decaying
|
Operating
|
| -
|
Entry into the ROOM LAMP OFF
state |
|
Condition 13
State
|
Description
|
Initial
Condition
|
ROOM
LAMP DECAY
|
Transition Condition
|
IGN1 ON
and OPEN 4 DOOR or Tailgate for 0.1 seconds
|
Operating
|
| -
|
Entry into the ROOM LAMP ON
state |
|

T1 : 20 ± 1 min, T2 : 30 ± 3 sec,
T3 : 100 ms.
Condition 14
State
|
Description
|
Initial
Condition
|
ROOM
LAMP ON & IGN1 ON & 4DOOR or Tailgate
OPEN
|
Transition Condition
|
4DOOR
AND Tailgate CLOSE
|
Operating
|
| -
|
Entry into the ROOM LAMP DECAYING
state |
| -
|
The ROOM LAMP is decayed for 2 ±
0.2 seconds and then, shall be
OFF. | |
Condition 15
State
|
Description
|
Initial
Condition
|
ROOM
LAMP ON & IGN1 ON & 4DOOR or Tailgate
OPEN
|
Transition Condition
|
IGN1
OFF
|
Operating
|
| -
|
Entry into the ROOM LAMP ON state
for 20min |
| -
|
ROOM LAMP ON for 20 ±
1minutes. | |
Condition 16
State
|
Description
|
Initial
Condition
|
ROOM
LAMP ON & IGN1 ON & 4DOOR or Tailgate
OPEN
|
Transition Condition
|
4DOOR
AND Tailgate CLOSE & IGN1 OFF
|
Operating
|
| -
|
Entry into the ROOM LAMP ON state
for 30s |
| -
|
ROOM LAMP ON for 30 ±
3seconds. | |

T1 : 20 ± 1 min, T2 : 30 ± 3 sec,
T3 : 100ms.
| 1. |
When the IGN1 is ON, there shall
be no blinking of the ROOM
LAMP. |
| 2. |
The decaying of the ROOM LAMP
should be more than 32
steps. | | |
| 18. |
POWER WINDOW TIMER
| (1) |
When the IGN2 SW is ON, then the Power
Window Relay output shall be
ON. |
| (2) |
When the IGN2 SW is OFF, then the Power
Window output shall be OFF after the output is maintained ON
for 30 seconds. |
| (3) |
In the condition of the Above (2), if
the driver’s or assist’s door is opened, then the output shall
be OFF immediately. |
| (4) |
In the state that the driver's or
assist's door is opened, if the IGN is OFF, then the Power
Window output shall be OFF. |
| (5) |
The SAFTEY POWER WINDOW ECU Output-port
shall be controlled the same as the POWER WINDOW RELAY
does.

T1 : 30 ± 3
sec. | |
| 19. |
Navigation wake up
| A. |
Navigation wake up control data
flow |

| A. |
Navigation wake up signal
control |
| (1) |
When KEY OUT, if TX UNLOCK is received,
Navigation Wake-Up Signal is
operating. |
| (2) |
Navigation Wake-Up Signal is repeated,
60ms ON / OFF, 8 times. |
| (3) |
After operating of Navigation Wake-up
signal by TX UNLOCK input, if TX UNLOCK is received in T2
(60sec), Navigation Wake-Up Signal is not
operating. |
| (4) |
If Key IN is ON during operating
Navigation Wake-Up Signal, Signal is maintained.

T1 : 60 ± 5 msec, T2 : 1 min ± 5
sec | |
| 20. |
DOOR LOCK/UNLOCK RELAY CONTROL
| (1) |
2-TURN UNLOCK SPECIFICATION

|
Unlock
relay
|
Door
unlock
|
Lock
relay
|
Central lock
|
OFF
|
OFF
|
ON
|
Central unlock
|
ON
|
ON
|
OFF
|
Driver unlock
|
OFF
|
ON
|
OFF
|
| |
| 21. |
CENTRAL DOOR LOCK/UNLOCK
| (1) |
After the driver's door key lock SW is
on, if the driver's door ACTUATOR UNLOCK SW changes from
UNLOCk to LOCK within 3s, ALL DOOR LOCK output shall be ON for
T1. But, in case of KEY IN and IGN1 SW ON, output shall be
inhibited. |
| (2) |
After the driver's door key unlock SW is
on, if the driver's door ACTUATOR UNLOCK SW changes from LOCK
to UNLOCK within 3s, ALL DOOR UNLOCK output shall be ON for
T1. |
| (3) |
When the TX (Transmitter) LOCK signal is
received, all DOOR LOCK output shall be ON for
T1. |
| (4) |
When the TX UNLOCK signal is received,
all DOOR UNLOCK output shall be ON for
T1. |
| (5) |
If the Door LOCK Switch (Power window)
is locked , all DOOR LOCK output shall be ON for
T1. |
| (6) |
If the Door UNLOCK Switch (Power window)
is unlocked, all DOOR UNLOCK output shall be ON for T1.But, in
ARM state, the operation by POWER WINDOW UNLOCK Switch shall
be inhibited. |
| (7) |
The LOCK/UNLOCK by the SAFETY KNOB is
non-interlocking. (Mechanical
operation) |
| (8) |
When connected to the BATTERY, there
shall be no malfunction.(there shall be no malfunction in the
KEY IN position) |
| (9) |
Don't receive the input with less than
60msec(KEY LOCK/UNLOCK SW). |
| (10) |
During output, if there are the output
request, the current output shall be OFF immediately, and
after 100ms delay, and then, perform the reverse direction
output. But, if there are the output request during 100ms
delay, perform the output for the last output request
occurred. |
| (11) |
In case of the Lock output and Unlock
output condition are occurred at the same tine, perform the
lock output and disregard the unlock
output. |
| (12) |
In case of all DOOR LOCK(UNLOCK) Switch
is LOCK(UNLOCK) state, the LOCK(UNLOCK) request in power
window always output. |
| (13) |
In case of DRIVER DOOR UNLOCK Switch is
UNLOCK state, the request of DRIVER DOOR UNLOCK does not
output. |
| (14) |
During DRIVER DOOR UNLOCK output, in
case of the output request of ALL DOOR UNLOCK, perform DRIVER
DOOR UNLOCK output according to ALL DOOR UNLOCK
output.

T1 : 0.5 ± 0.1 sec, T2 : MAX 3
sec. | |
| 22. |
2-TURN UNLOCK
| (1) |
IF DRIVER KEY UNLOCK SW is OFF >ON
(DRIVER DOOR LOCK SW is UNLOCK mechanically and BCM doesn't
output) and then the Driver's ACTUATOR UNLOCK SW is LOCK >
UNLOCK within 3s and Driver key unlock SW is OFF > ON
within T1, all door unlock output shall be ON for
T2.. |
| (2) |
IF DRIVER KEY UNLOCK SW is OFF > ON
(DRIVER DOOR LOCK SW is UNLOCK mechanically and BCM doesn't
output) and then the Driver's ACTUATOR UNLOCK SW is LOCK >
UNLOCK within 3s and receives TX UNLOCK within T1, the UNLOCK
output shall be ON to all doors for
T2. |
| (3) |
When the TX UNLOCK signal is received,
the DRIVER DOOR UNLOCK output shall be ON for T2. But, if the
TX UNLOCK signal is received within T1, the UNLOCK output
shall be ON to all doors for
T2. |
| (4) |
If after the TX UNLOCK signal is
received, and after the DRIVER KEY UNLOCK SW is turned to ON
from OFF (Driver door lock sw become UNLOCK, and BCM does not
operate) within T1, actuator unlock sw is UNLOCK in 3s, the
UNLOCK output shall be ON to all doors for
T2. |
| (5) |
Even if other registered TX signal
within T1 is received, the signal shall regard as the same TX
signal. |
| (6) |
The DOOR LOCK(UNLOCK) output produced by
the change of the DRIVER DOOR LOCK SW(KNOB) shall be not
output.

T1 : 4 ± 1 sec, T2 : 0.5 ± 0.1 sec,
T3 : Max 3
sec | |
| 23. |
IGN KEY REMINDER
| (1) |
If the Vehicle speed is over 3Km/h, then
this function doesn't act on. |
| (2) |
If KEY IN Switch is IN & the
driver's door is opened & the driver's DOOR UNLOCK Switch
is locked, then after 0.5 seconds, the unlock signal shall be
output to the driver's door for
1s. |
| (3) |
If it is in state of that KEY IN SW is
IN & assist's DOOR is OPEN & assist's DOOR UNLOCK SW
is LOCK, and after 0.5s, and then perform the ALL DOOR UNLOCK
output for 1 second. |
| (4) |
When (2) items are met at the same time,
after 0.5 seconds, the unlock signal shall be output to all
doors for 1 second in conformity with (3)
item. |
| (5) |
Although the unlock signal is output for
1 s by the (2), (3) items, if the lock state is maintained,
the unlock signal shall be output at maximum three times
(except for 1s output). (1s cycle: 0.5s
ON/OFF) |
| (6) |
After perform (5) items, in case of LOCK
state is maintained, and in case of DOOR CLOSE, and then
attempt the ALL DOOR UNLOCK one
time. |
| (7) |
In the KEY IN Switch is IN state, if the
driver's door is closed within 0.5 seconds as soon as the
driver's DOOR UNLOCK SW is turned to the LOCK from the UNLOCK,
the unlock signal shall be output to the driver's door for 1 s
one time. |
| (8) |
In the KEY IN Switch is IN state, if the
assist's door is closed within 0.5 seconds as soon as the
assist's DOOR UNLOCK Switch is turned to the LOCK from the
UNLOCK, the unlock signal shall be output to all doors for 1 s
one time. |
| (9) |
In the KEY IN Switch is IN state, if the
driver's DOOR UNLOCK Switch is turned to the LOCK from the
UNLOCK within 0.5 seconds as soon as the driver’s door is
turned to the closed state from the opened state, then the
Unlock signal shall be output to the driver's door for 1
second one time. |
| (10) |
In the KEY IN Switch is IN state, if the
assist's DOOR UNLOCK Switch is turned to the LOCK from the
UNLOCK within 0.5 seconds as soon as the assist's door is
turned to the closed state from the opened state, then the
Unlock signal shall be output to all doors for 1 second one
time. |
| (11) |
In the KEY IN state, after the DRIVER
DOOR or ASSIST DOOR are opened, if the doors are locked by the
Power window LOCK Switch, the unlock signal shall be output to
all doors. |
| (12) |
Even if the condition is not maintained
for 0.5s after the UNLOCK condition is satisfied, the unlock
signal shall be output. But, after the condition is satisfied
as the result that the DOOR LOCK Switch is turned to the LOCK
from the UNLOCK, if the KEY IN Switch is OFF at the passage
time of 0.5s, the unlock signal shall not be
output.

T1, T3 : 0.5 ± 0.1 sec, T2 : 1 ± 0.1
sec,
T4 : 0.5 sec
Max | |
| 24. |
CRASH DOOR UNLOCK
| (1) |
In the IGN KEY ON state, whenever the
AIR BAG signal is received, the unlock signal shall be output
always. |
| (2) |
During the unlock output, even if the
IGN KEY ON is turned to the OFF from the ON, the unlock output
is maintained for the remained
time. |
| (3) |
After the UNLOCK output, if the DRIVER
or ASSIST, REAR DOOR LOCK SW are turned to the LOCK from the
UNLOCK, the unlock signal shall be output for
T3. |
| (4) |
The AUTO DOOR LOCK function is not
performed in the CRASH UNLOCK
condition. |
| (5) |
The CRASH DOOR UNLOCK function is prior
to the LOCK/UNLOCK control by the other
functions. |
| (6) |
The LOCK/UNLOCK requirement by the other
functions is disregarded during the CRASH DOOR UNLOCK output
or after it. But, if the IGN KEY OFF, the LOCK/UNLOCK control
by the other functions shall be performed.

T1 : 0.2 sec, T2 : 40 msec,
T3 : 5 ± 0.5 sec.
*1 ON : IGN KEY ON
OFF : IGN KEY
OFF | |
| 25. |
2-turn Mode change fuction
| (1) |
If Lock & Unlock buttons of RKE are
pushed together more than 4sec, RKE transmits Two Turn Unlock
Set/Reset Frame. |
| (2) |
If DATA of (1) is received, BCM changes
Two Turn Unlock Mode. |
| (3) |
In case of Set state, if (1) data is
received, mode is changed to Reset, and in case of Reset state
if (1) data is received, mode is changed to
Set. |
| (4) |
In case of mode change, BCM output
Hazard Lamp 4 times On/Off(1sec cycle) .

T1 : 4.5sec within, T2 : 4sec,
T3 : 1 ± 0.1
sec. | |
| 26. |
3KM SIGNAL OUTPUT CONTROL
If the vehicle speed is maintained at more
than 3km/h for 2~3 seconds in the IGN1 ON state, the signal of 3 KM
Output-port shall be ON.

T1 : 2.5 ± 0.5