| 1. |
Connect the GDS on the Data Link Connector
(DLC). |
| 2. |
Measure the output voltage of the BPS at idle
and IG ON.
Specification:
Refer to
"Specification"
|
|
| 1. |
Turn the ignition switch OFF and disconnect
the battery negative (-) cable. |
| 2. |
Disconnect the barometric pressure sensor
connector (A). |
| 3. |
Remove the installation bolt (B), and then
remove the sensor from the air cleaner assembly.

|
| •
|
Install the component with the specified
torques. |
| •
|
Note that internal damage may occur when
the component is dropped. If the component has been dropped,
inspect before
installing. | |
| •
|
Insert the sensor in the installation
hole and be careful not to damage when
installation.
| |
| 1. |
Installation is reverse of
removal.
Barometric
pressure sensor installation bolt:
3.9 ~ 5.9 N.m (0.4 ~ 0.6 kgf.m, 2.9 ~
4.3 lb-ft)
| | |