RPAS (Rear Parking
Assist System) is an electronic driving aid that warns the driver to be
cautious while parking or in low speed environments. The sensor uses
ultrasonic waves to detect objects within proximity of the
vehicle.
RPAS consists of four
RPS sensors which are detecting the obstacles and transmit the result
separated into three warning levels, the first, second and third to BCM by
Lin communication. BCM decides the alarm level by the transmitted
communication message from the slave sensors, then operate the buzzer or
transmits the data for display.
System Block Diagram
System Operation Specification.
Sensing Area
Horizontal Sensing Area
Vertical Sensing Area
Distance Measurement
Transmission and
Reception are executed with one sensor
(RL, RCL, RCR, RR each
sensor execution)
(RCL → RL, RCL → RCR,
RCR → RCL, RCR → RR Execution in order)
With two or three
sensors, one of them sends the transmission and the others get the
reception.
With two or three
sensors, the one sensor performs both transmission and reception, and the
others perform only reception.
RPAS alarm system
When the RPAS sensor
detects the object, warning is operated by audible alarm device as like
buzzer. RPAS sensor sends data to BCM with LIN communication and BCM
implements audible warning for each RPAS SENSOR by priority. And it
performs a role of gateway only when it sends visible alarm device such as
Cluster.
System Operation Spec
When the system has the
power (after IGN ON and R gear), MICOM checks every sensor channel. In
case it finds any error, it sounds 300ms buzzer 500ms afterward. But it
finds any error even a sensor, it sounds buzzer corresponding fault sensor
instead of initial starting alarm. Function for normal mode entrance is as
below
With R Gear, system
function is as below
With R gear releasing,
system function is as below
※acceptable error range
on waveform ±10%
Alarm Output Specification classified by
distance between sensors
Condition logic
according to priority of alarm level is as below. (the identical
sensor)
*α value
definition
*β value
definition
Alarm control by sensing
distance is as below
Visible Alarm Indicator Specification
When the gear is applied
to R, cluster lights the indicator as below figure.
When the system finds an
object, it lights indicator immediately. During sensing an object, if
there is no object, it lights indicator that is no alarm status for two
seconds and then turns out afterward detecting an object.
(But when it turns third
step alarm to No alarm status, it lights third step alarm for two second
and turns out.)
Communication Standard
This section defines the
communication between RPAS and BCM.
RPAS send a detecting
result of object and sensor diagnosis result to BCM according to this
document, and BCM takes a role to alarm.
Indicator shows the
transmitted position and alarm data, in alarm case, it finds the nearest
DATA and alarms the nearest DATA first.
(Ex. In case, RL is
first step alarm and RR is third step, RR alarm has
priority.) |