OPERATION METHOD (SELF-DIAGNOSIS)
The Full Automatic
Control air conditioning module self test feature will detect electrical
malfunction and provide error codes for system components with suspected
failures.

DIAGNOSTIC TROUBLE CODE DESCRIPTION
| 1. |
A/C system is turned OFF during self
diagnosis. The result of self diagnosis is displayed using 2 digits
of the temperature display. |
| 2. |
Diagnostic trouble codes are displayed during
self diagnosis. However, after diagnosis is complete, relevant data
is not stored in memory. |
| 3. |
Self diagnosis of photo sensor is performed
using a light bulb over 60W placed within 40cm with sun load
applied.
|
Without sun load, photo sensor error
code
displays. | |
DTC CHART
If a malfunction code is
displayed during the DTC check, check the circuit listed for that code in
the table below.
|
DTC
code |
Detection
item |
Trouble
area |
|
00 |
Normal |
| •
|
Harness or connector between incar
sensor and A/C control
assembly |
|
|
11 |
Open INCAR Sensor circuit |
|
12 |
Shorted INCAR Sensor
circuit |
|
13 |
Open Ambient sensor circuit |
| •
|
Harness or connector between ambient
sensor and A/C control
assembly |
|
|
14 |
Shorted Ambient sensor
circuit |
|
15 |
Open water temp. sensor |
| •
|
Harness or connector between water temp.
sensor and A/C control
assembly |
|
|
16 |
Shorted water temp. sensor |
|
17 |
Open evap. sensor |
| •
|
Harness or connector between evap.
sensor and A/C control
assembly |
|
|
18 |
Shorted evap. sensor |
|
19 |
Open or shorted temp. door
potentiometer |
| •
|
Harness or connector between temp. door
potentiometer and A/C control
assembly | |
|
20 |
Defective temp. door
potentiometer |
| •
|
Temp. door
potentiometer | |
FAILURE SAFE FUNCTION
|
NO. |
Item |
Description |
Fail-safe |
|
1 |
INCAR SENSOR |
Short/open circuit of IN CAR
SENSOR |
Once diagnosis is occurs, system is regarded
as 25°C constant. |
|
2 |
AMBIENT SENSOR |
Short/open circuit of AMBIENT
SENSOR |
Once diagnosis is occurs, system is regarded
as 20°C constant. |
|
3 |
EVAPORATOR TEMP. SENSOR |
Short/open circuit of EVAPORATOR TEMP.
SENSOR |
Once diagnosis is occurs, system is regarded
as -2°C constant. |
|
4 |
WATER TEMP. SENSOR |
Short/open circuit of WATER TEMP.
SENSOR |
| •
|
After 10 minutes at ignition ON
condition, the water temp. sensor will be
failed. | |
|
5 |
TEMP. DOOR POTENTIOMETER |
Short/open circuit of TEMP. DOOR
POTENTIOMETER |
| •
|
17°C constant → when 24.5°C : MAX
COOL |
| •
|
25°C constant → when 32°C : MAX
HOT | |