The SRS airbag
system has sophisticated electrical and electronic components. Therefore
the airbag operating components should be handled very carefully.
SRSCM (Supplement Restraint System Control Module)
SRSCM
determines when to deploy the airbag module by sensing the frontal and
side impact force through the built in sensor SRSCM.
SRS HARNESS
The SRS
harness is wrapped in yellow tube to identify it from other system
harnesses. A shorting bar is included inside the wiring connectors of DAB,
PAB, DSAB, PSAB and BPT inflator side. The shorting bar shorts the current
flow when the connectors are disconnected. The circuits to the inflator
module are shorted in this way to help prevent unwanted deployment of the
airbag when serving the airbag module.
SRSCM INDEPENDENT LAMP ACTIVATION
The SRS
malfunction indicator lamp (MIL) is located on the instrument cluster to
provide information about SRS operating conditions.
There are certain fault
conditions in which the SRSCM (SRS Control Module) cannot function and
thus cannot control the operation of the lamp. In these cases, the lamp is
directly activated by circuitry that operates independently of the SRSCM,
as follows :
MIL OPERATING METHOD
CLOCK SPRING
The clock
spring (coil spring) consists of two current carrying coils. It is
attached between the steering column and the steering wheel. It allows
rotation of the steering wheel while maintaining continuous contact of the
deployment loop through the inflator module.
The steering wheel must
be fitted correctly to the steering column with the clock spring at the
neutral position, otherwise cable disconnection and other troubles may
result.
PPD (Passenger Presence Detection)
The Passenger Presence
Detection system detects the presence of passenger in the front passenger
seat. The system is designed primarily to prevent replacement of airbag
components that fire needlessly in an accident. The PPD system consistsof
a weight sensor unit.
The threshold for the
PPD is : occupied (15 kg, 33 lb); not occupied (0.6 kg, 1.3 lb). The
sensor characteristics are :
RP ≤ 50 kΩ for
W ≥ 15 kg
RP > 50 kΩ for W <
0.6 kg
(RP :
Resistance of force sensing resistor)
(W : Mass of
weight)
CHECK PROCEDURES
|