The MICRO 570
Analyzer provides the ability to test the charging and starting systems,
including the battery, starter and alternator.
|
Because of the possibility of personal injury,
always use extreme caution and appropriate eye protection when
working with batteries.

|
KEYPAD
The MICRO570
button on the key pad provide the following functions :

BATTERY TEST PROCEDURE
| 1. |
Connect the tester to the
battery.
| A. |
Red clamp to battery positive (+)
terminal. |
| B. |
Black clamp to battery negative (-)
terminal.

|
|
Connect clamps securely. If "CHECK
CONNECTION" message is displyed on the screen, reconnect
clamps
securely. | |
| 2. |
The tester will ask if the battery is
connected "IN A VEHICLE" or "OUT OF A VEHICLE".
Make your selection by pressing the arrow
buttons; then press ENTER.

|
| 3. |
Choose eigher CCA or CCP and press the ENTER
button.

| -
|
CCA : Cold cranking amps, is an
SAE specification for cranking batteried at 0°F
(-18°C). |
| -
|
CCP : Cold cranking amps, is an
SAe specification for korean manufacturer's for cranking
batteried at 0°F
(-18°C) | | |
| 4. |
Set the CCA value displyed on the screen to
the CCA value marked on the battery label by pressing up and down
buttons and press ENTER.

|
The battery ratings(CCA) displyed on the
tester must be identical to the ratings marked on battery
label. | |
| 5. |
The tester (Micro570) displays battery test
results including voltage and battery ratings.
A relevant action must be given according to
the test results by referring to the battery test results as shown
in the table below.

|
| 6. |
To conduct starter test, continuously, press
ENTER.
BATTERY TEST RESULTS
|
RESULT ON
PRINTER |
REMEDY |
|
Good battery |
No action is required |
|
Good recharge |
Battery is in a good state
Recharge the battery and
use |
|
Charge & Retest |
Battery is not charged
properly
→ Charge and test the battery again
(Failure to charge the battery fully may read incorrect
measurement value) |
|
Replace battery |
→ Replace battery and recheck the
charging system. (Improper connection between battery and
vehicle cables may cause "REPLACE BATTERY", retest the battery
after removing cables and connecting the tester to the battery
terminal directly prior to replacing the
battery) |
|
Bad cell-replace |
→ Charge and retest the battery. And
than, test results may cause "REPLACE BATTERY", replace
battery and recheck the charging
system |
|
Whenever filing a claim for battery, the
print out of the battery test results must be
attached. | |
STARTER TEST PROCEDURE
| 1. |
After the battery test, press ENTER
immediately for the starter test.

|
| 2. |
After pressing ENTER key, start the
engine.

|
| 3. |
Cranking voltage and starter test results will
be displayed on the screen.
Take a relevant action according to the test
results by referring to the starter test results as given
below.

|
| 4. |
To continue charging system test, press
ENTER.
STARTER TEST RESULTS
|
RESULT ON
PRINTER |
REMEDY |
|
Cranking voltage normal |
System shows a normal starter
draw |
|
Cranking voltage low |
Cranking voltage is lower than normal
level
→ Check starter |
|
Charge battery |
The state of battery charge is too low
to test
→ Charge the battery and
retest |
|
Replace battery |
→ Replace battery
If the vehicle is not started though the
battery condition of "Good and fully charged" is
displayed.
→ Check wiring for open circuit, battery
cable connection, starter and repair or replace as
necessary.
→ If the engine does crank, check fuel
system. |
|
When testing the vehicle with old diesel
engines, the test result will not be favorable if the glow
plug is not heated. Conduct the test after warming up the
engine for 5
minutes. | |
CHARGING SYSTEM TEST PROCEDURE
| 1. |
Press ENTER to begin charging system
test.

|
| 2. |
If ENTER button is pressed, the tester
displays the actual voltage of alternator.
Press ENTER to test the charging
system.

|
| 3. |
Turn off all electrical load and rev engine
for 5 seconds with pressing the accelerator pedal.

|
| 4. |
Press ENTER.

|
| 5. |
The MICRO 570 analyzer charging system output
at idle for comparision to other readings.

|
| 6. |
Take a relevant action according to the test
results by referring to the table below after shutting off the
engine and disconnect the tester clamps from the
battery.

CHARGING SYSTEM TEST RESULTS
|
RESULT ON
PRINTER |
REMEDY |
|
Charging system normal/Diode ripple
normal |
Charging system is
normal |
|
No charging voltage |
Alternator does not supply charging
current to battery
→ Check belts, connection between
alternator and battery
Replace belts or cable or alternator as
necessary |
|
Low charging voltage |
Alternator does not supply charging
current to battery and electrical load to system
fully
→ Check belts and alternator and replace
as necessary |
|
High charging voltage |
The voltage from alternator to battery
is higher than normal limit during voltage
regulating.
→ Check connection and ground and
replace regulator as necessary
→ Check electrolyte level in the
battery |
|
Excess ripple detected |
One or more diodes in the alternator is
not functioning properly
→ Check alternator mounting and belts
and replace as
necessary |
|