Home › Emission Control System › Troubleshooting

P0401 Exhaust Gas Recirculation Malfunction

P
DTC
Diagnostic item
P0401
Exhaust Gas Recirculation Malfunction

DESCRIPTION
The Exhaust Gas Recirculation (EGR) system is designed to introduce exhaustgas into the combustion chamber. This lowers combustion temperatures and reducesthe formation of oxides of nitrogen. The amount and timing of exhaust gasintroduced into the combustion cycle varies by such factors as engine speed,engine vacuum, exhaust system back pressure, coolant temperature and throttleposition.
TROUBLESHOOTING GUIDE
DTC detection condition
Probable cause
Background
When the EGR solenoid switches from OFF to ON while the engine is running,EGR gas flows.
The engine control module checks for changes in the EGR gas flow signal.
Check Area
Engine coolant temperature is higher than 80°C (176°F).
Engine speed is between 1,000 and 2,000 rpm.
Closed throttle position switch: ON
Monitoring Time: 2 sec.
Judgment Criteria
The exhaust gas changes little when the EGR solenoid is switched on.
Monitored only once per trip.
EGR valve does not open
EGR control vacuum is too low
EGR solenoid failed
Open or shorted EGR solenoid circuit, or loose connector
Manifold absolute pressure sensor failed
Engine control module failed

CIRCUIT DIAGRAM

TEST PROCEDURE