Home › Emission Control System › Troubleshooting

P0420 Main Catalyst Efficiency Below Threshold (Bank 1)

P
DTC
P0420
Main Catalyst Efficiency Below Threshold (Bank 1)

DESCRIPTION
The ECM uses dual oxygen sensors to monitor the efficiency of the manifold catalytic converter (warm-up catalytic converter). By monitoring the oxygen storage capacity of a catalyst, its efficiency can be indirectly calculated. The upstream (front) HO2S is used to detect the amount of oxygen in the exhaust gas before it enters the catalytic converter. A low voltage indicates high oxygen contents (lean air mixture). A high voltage indicates low oxygen contents (rich air mixture).When the catalyst efficiency drops, no chemical reaction takes place. This means the concentration of oxygen will be the same rear as front. The output voltage of the rear HO2S copies the voltage of the front HO2S.To monitor the system, the lean-to-rich switches of front HO2S to rear HO2S is counted. The ratio of rear switches to front switches is used to determine whether the catalyst is operating properly. An effective catalyst will have fewer rear switches than front switches, that is, a ratio closer to zero.
DTC DETECTING CONDITION
DTC No
Detecting Condition & Limp Home
Suspected area
P0420
Detecting Condition
The integral value of subtraction the rear HO2S filtered from the rear HO2S is over threshold value.
Enable Condition
- No relevant failure
- Vehicle speed > 4.8 km/h
- Catalyst model temperature: 300~730°C
- Engine coolant temperature > 74°C(165.2°F)
- Engine speed: 1200~3500 RPM
- 110 mg/stroke < Air mass flow < 350mg/stroke
- Lambda control active
- Downstream O2 sensor operative ready
- Engine operating state : part load
- 11 < Battery voltage < 16V
Limp Home
None
- Air leakage
- HO2S
- Catalytic converter
- ECM

INSPECTION PROCEDURES

Proceed with ECM problem procedure.