Home › Fuel System › Troubleshooting

P0131 HO2S Circuit Low Input (Bank 1, Sensor 1)

P
DTC
P0131
Linear O2 Sensor Circuit Low Input (Bank1, Sensor1)

DESCRIPTION
The linear oxygen sensor is mounted on the front side of Catalytic Converter (warm-up catalytic converter) or in the front exhaust pipe, which detects a wide range of air/fuel ratio in the exhaust gas from rich to lean regions. This linear oxygen sensor produces a current that corresponds to a specific air/fuel ratio. The ECM monitors this signal and determines whether the air/fuel mixture is rich or lean. The ECM constantly monitors the HO2S and increases or decreases the fuel injection duration by using the HO2S signal, which is called closed-loop fuel control operation.
DTC DETECTING CONDITION
DTC No
Detecting Condition & Limp Home
Suspected area
P0131
Detecting Condition
Enable Condition
- Sensor pre-heating and full heating phases finished
- 10 < Battery voltage < 16V
Limp Home
Lambda open loop control
- Short to ground in HO2S circuit
- Front HO2S
- ECM

SCHEMATIC DIAGRAM

INSPECTION PROCEDURES

Proceed with ECM problem procedure.