DESCRIPTION
The linear
oxygen sensor is mounted on the front side of Catalytic Converter (warm-up
catalytic converter) or in the front exhaust pipe, which detects a wide
range of air/fuel ratio in the exhaust gas from rich to lean regions. This
linear oxygen sensor produces a current that corresponds to a specific
air/fuel ratio. The ECM monitors this signal and determines whether the
air/fuel mixture is rich or lean. The ECM constantly monitors the HO2S and
increases or decreases the fuel injection duration by using the HO2S
signal, which is called closed-loop fuel control operation.
DTC DETECTING CONDITION
SCHEMATIC DIAGRAM
INSPECTION PROCEDURES
|