Home › Fuel System › Troubleshooting

P0132 Oxygen Sensor Circuit Malfunction (Open) (Bank 1, Sensor 1)

p
DTC
Diagnostic item
P0132
P0133
P0154
P0134
Oxygen Sensor Circuit Malfunction (Open)
Oxygen Sensor Circuit Malfunction (Bank 1, Sensor 1)
Oxygen Sensor Circuit Malfunction (Bank 2, Sensor 1)
Oxygen Sensor Circuit Malfunction (No Activity)

DESCRIPTION
To obtain a high purification rate for the CO, HC and NOx components of theexhaust gas, a three way catalytic converter is used, but for the most efficientuse of the three-way catalytic inverter, the ratio of the air must be preciselycontrolled so that it is always close to the stoichiometric air-fuel ratio.The oxygen sensor has the characteristic whereby its output voltage changessuddenly in the vicinity of the stoichiometric air-fuel ratio. This characteristicis used to detect the oxygen concentration in the exhaust gas and providefeedback to the computer for control of the air-fuel ratio. When the air-fuelratio becomes LEAN, the oxygen concentration in the exhaust increases andthe oxygen sensor informs the PCM of the LEAN condition. When the air-fuelratio is RICHER than the stoichiometric air-fuel ratio the oxygen concentrationin the exhaust gas is reduced and the oxygen sensor informs the PCM of theRICH condition. The PCM uses the voltage from the oxygen sensor whether the air-fuel ratiois RICH or LEAN and controls the injection time accordingly. However, if amalfunctioning oxygen sensor causes an abnormal output voltage, the PCM isunable to perform an accurate air-fuel ratio control. The heated oxygen sensorsinclude a heater which heats the sensing element. The heater is controlledby the PCM. When the intake air volume is low (the temperature of the exhaustgas is low), current flows to the heater to heat the sensor for accurate oxygenconcentration detection.
TROUBLESHOOTING GUIDE
DTC detection condition
Probable cause
Background
When the heated oxygen sensor begins to deteriorate, the oxygen sensor signalresponse becomes poor.
The Powertrain Control Module forcibly varies the air/fuel mixture to makeit leaner and richer and checks the response speed of the heated oxygen sensor.
In addition, the Powertrain Control Module also checks for an open circuitin the heated oxygen sensor output line.
Malfunction; out-of-range
Coolant temperature sensor: Normal.
Heated oxygen sensor signal voltage has continued to be 0.1V or lower for3 min. or more after the starting sequence was completed.
Engine Coolant Temperature is higher than 80°C (176°F).
Engine speed is higher than 1,200 rpm.
Engine load is 25% or more. Judgment Criteria
Input voltage supplied to the Powertrain Control Module interface circuitis 4.5V or more when 5V is applied to the heated oxygen sensor output linevia a resistor.
Proper Operation
Coolant temperature sensor: Normal.
Engine Coolant Temperature is 50°C (122°F) or more.
Engine speed is between 1,500 and 3,000 rpm or 1,100 and 3,000 rpm.
Engine load is 25 - 60%.
Intake air temperature is -10°C (14°F) or more.
Under the closed loop air-fuel control.
Monitoring Time: 8 sec.
Failure Criteria
When the air-fuel ratio is forcibly changed (lean to rich and rich to lean),the heated oxygen sensor signal doesn't provide response within 1.28 sec.
Monitored only once per trip.
Heated oxygen sensor deteriorated
Open circuit in heated oxygen sensor output line
Powertrain control module failed

CIRCUIT DIAGRAM

TEST PROCEDURE