Home
›
Fuel System
›
Troubleshooting
P0133 Oxygen Sensor Circuit Malfunction (Bank 1, Sensor 1)
P
DTC
P0133
Linear O2 Sensor Circuit Slow Responsive (Bank1, Sensor1)
DESCRIPTION
Refer to DTC P0131
DTC DETECTING CONDITION
DTC No
Detecting Condition & Limp Home
Suspected area
P0133
Detecting Condition
Sum of lean/rich period > calculated period
Enable Condition
- 120mg/STK < Mass air flow < 400mg/STK
- No lambda control limitation
- 1000 RPM < engine speed at idle < 3500 RPM
Limp Home
Lambda open loop control
- Abnormal combustion
- Improper fuel pressure
- Fuel delivery system
- Intake system
- Exhaust system
- Front HO2S
SCHEMATIC DIAGRAM
Refer to DTC P0131
INSPECTION PROCEDURES
Proceed with ECM problem procedure.