Home › Fuel System › Troubleshooting

P0135 Oxygen Sensor Heater Circuit Malfunction (Bank 1, Sensor 1)

p
DTC
Diagnostic item
P0135
P0155
Oxygen Sensor Heater Circuit Malfunction (Bank 1, Sensor 1)
Oxygen Sensor Heater Circuit Malfunction (Bank 2, Sensor 1)

DESCRIPTION
To obtain a high purification rate for the CO, HC and NOx components of theexhaust gas, a three way catalytic converter is used, but for the most efficientuse of the three-way catalytic inverter, the ratio of the air must be preciselycontrolled so that it is always close to the stoichiometric air-fuel ratio.The oxygen sensor has the characteristic whereby its output voltage changessuddenly in the vicinity of the stoichiometric air-fuel ratio. This characteristicis used to detect the oxygen concentration in the exhaust gas and providefeedback to the computer for control of the air-fuel ratio. When the air-fuelratio becomes LEAN, the oxygen concentration in the exhaust increases andthe oxygen sensor informs the PCM of the LEAN condition. When the air-fuelratio is RICHER than the stoichiometric air-fuel ratio the oxygen concentrationin the exhaust gas is reduced and the oxygen sensor informs the PCM of theRICH condition. The PCM uses the voltage from the oxygen sensor whether the air-fuel ratiois RICH or LEAN and controls the injection time accordingly. However, if amalfunctioning oxygen sensor causes an abnormal output voltage, the PCM isunable to perform an accurate air-fuel ratio control. The heated oxygen sensorsinclude a heater which heats the sensing element. The heater is controlledby the PCM. When the intake air volume is low (the temperature of the exhaustgas is low), current flows to the heater to heat the sensor for accurate oxygenconcentration detection.
TROUBLESHOOTING GUIDE
DTC detection condition
Probable cause
Background
The Powertrain Control Module checks whether the heater current is withina specified range when the heater is energized.
Check Area
Battery voltage is between 12 and 16V.
Judgment Criteria
The heater current of the front heated oxygen sensor heater (Bank 1 Sensor1 and Bank 2 Sensor 1) has continued to be 0.2 A or less, or 3.5 A or higherfor 6 sec.
Monitored only once per trip.
Open or shorted oxygen sensor heater circuit
Open circuit in oxygen sensor heater
Powertrain control module failed

CIRCUIT DIAGRAM

TEST PROCEDURE