Home › Fuel System › Troubleshooting

P0136 Oxygen Sensor Circuit Malfunction (Bank 1, Sensor 2)

p
DTC
Diagnostic item
P0136
P0139
P0140
Oxygen Sensor Circuit Malfunction (Bank 1, Sensor 2)
Oxygen Sensor Circuit Range/Performance Problem (Bank 1, Sensor 2)
Oxygen Sensor Circuit Malfunction - Short (Bank 1, Sensor 2)

DESCRIPTION
To obtain a high purification rate for the CO, HC and NOx components of theexhaust gas, a three way catalytic converter is used, but for the most efficientuse of the three-way catalytic inverter, the ratio of the air must be preciselycontrolled so that it is always close to the stoichiometric air-fuel ratio.The oxygen sensor has the characteristic whereby its output voltage changessuddenly in the vicinity of the stoichiometric air-fuel ratio. This characteristicis used to detect the oxygen concentration in the exhaust gas and providefeedback to the computer for control of the air-fuel ratio. When the air-fuelratio becomes LEAN, the oxygen concentration in the exhaust increases andthe oxygen sensor informs the PCM of the LEAN condition. When the air-fuelratio is RICHER than the stoichiometric air-fuel ratio the oxygen concentrationin the exhaust gas is reduced and the oxygen sensor informs the PCM of theRICH condition. The PCM uses the voltage from the oxygen sensor whether the air-fuel ratiois RICH or LEAN and controls the injection time accordingly. However, if amalfunctioning oxygen sensor causes an abnormal output voltage, the PCM isunable to perform an accurate air-fuel ratio control. The heated oxygen sensorsinclude a heater which heats the sensing element. The heater is controlledby the PCM. When the intake air volume is low (the temperature of the exhaustgas is low), current flows to the heater to heat the sensor for accurate oxygenconcentration detection.
TROUBLESHOOTING GUIDE
DTC detection condition
Probable cause
Background
The Powertrain Control Module checks for an open circuit in the heated oxygensensor output line.
Normal values
Coolant temperature sensor: Normal.
Heated oxygen sensor signal voltage has continued to be 0.1V or lower for3 min. or more after the staring sequence was completed.
Engine coolant temperature is 80°C (176°F) or more.
Engine speed is higher than 1,200 r/min.
Engine load is 25% or more.
Monitoring Time: 7 - 10 sec.
Items to Check
Input voltage supplied to the Powertrain Control Module interface circuitis 4.5V or more when 5V is applied to the heated oxygen sensor output linevia a resistor.
Making the air-fuel ratio 15% richer doesn't result in raising the heatedoxygen sensor output voltage beyond 0.1V.
Heated oxygen sensor failed
Open circuit in heated oxygen sensor output line
Powertrain control module failed

CIRCUIT DIAGRAM

TEST PROCEDURE