| 4. |
With the thermostatic switch connector in
couple state, install a voltmeter between 2 and 3 (-) terminal and
check whether there is change in voltage between terminals according
to the temperature of the evaporator surface.

* Thermostatic switch operating
characteristics
|
This check should be carried out on the
back probes of the thermostatic switch when it is in coupled
state.
If above condition is not satisfied,
remove the evaporator unit and replace the thermostatic
switch. |
|
Operating
temp |
Thermostatic
switch operation |
Terminal
voltage (2 and 3) |
Remarks |
|
1.5±1.0°C
(34.7±1.8°F) |
OFF |
0V |
Compressor clutch should be
disengaged |
|
4.3±1.0°C
(39.7°1.8°F) |
ON |
12V |
Compressor clutch should be
engaged |
|

|
|

|
|
Operation
| 1. |
When the resistance (the
temperature of the evaporator) in the thermistor
increases:
→ TR1 "ON" → TR2 "ON" →
Thermostatic switch
"ON" |
| 2. |
When the resistance (the
temperature of the evaporator) in the thermistor
decreases:
→ TR1 "OFF" → TR2 "OFF" →
Thermostatic switch
"OFF" | |
|