DESCRIPTION
The ECM uses
dual oxygen sensors to monitor the efficiency of the manifold catalytic
converter (warm-up catalytic converter). By monitoring the oxygen storage
capacity of a catalyst, its efficiency can be indirectly calculated. The
upstream (front) HO2S is used to detect the amount of oxygen in the
exhaust gas before it enters the catalytic converter. A low voltage
indicates high oxygen contents (lean air mixture). A high voltage
indicates low oxygen contents (rich air mixture).When the catalyst
efficiency drops, no chemical reaction takes place. This means the
concentration of oxygen will be the same rear as front. The output voltage
of the rear HO2S copies the voltage of the front HO2S.To monitor the
system, the lean-to-rich switches of front HO2S to rear HO2S is counted.
The ratio of rear switches to front switches is used to determine whether
the catalyst is operating properly. An effective catalyst will have fewer
rear switches than front switches, that is, a ratio closer to zero.
DTC DETECTING CONDITION
INSPECTION PROCEDURES
|