DESCRIPTION
The
evaporative system prevents hydrocarbon vapor escaping from the fuel tank
into the atmosphere where it would form photochemical smog. Gasoline vapor
is collected in the charcoal canister. The Fuel Tank Pressure Sensor
(FTPS) is an integral part of the evaporative monitoring system. The ECM
monitors the FTPS signal to detect vacuum decay and excess vacuum. The
FTPS measures the difference between the air pressure in the fuel tank and
outside air pressure to checks purge solenoid valve operation and leak
detection in the evaporative emissions system by monitoring pressure and
vacuum levels in the fuel tank during purge solenoid valve operating
cycles.
DTC DETECTING CONDITION
SPECIFICATIONS
SCHEMATIC DIAGRAM
INSPECTION PROCEDURES
|