P0112 Intake Air Temperature Circuit Low Input

p
DTC
P0112
Intake Air Temperature Circuit Low Input

Description
The intake air temperature sensor (IATS) is mounted on the surge tank for detecting the intake air temperature. The IATS uses a thermistor whose resistance changes with the temperature. The electrical resistance of the IATS decreases as the temperature increases, and increases as the temperature decreases.The 5 V power source in the ECM is supplied to the IATS via a resistor in the ECM. That is, the resistor in the ECM and the thermistor in the IATS are connected in series. When the resistance value of the thermistor in IATS changes according to the intake air temperature, the signal voltage also changes.Using this signal, the information of the intake air temperature, the ECM corrects basic fuel injection duration and ignition timing.
DTC DETECTING CONDITION
DTC No
Detecting Condition & Limp Home
Suspect area
P0112
Detecting Condition
Intake air temperature > 117.75°C (243.95°F)
Enable Condition
- immediately after start
Limp Home
? The limp home value of IATS depends on ECTS
No failure detected on ECTS
- If engine coolant temperature < 69.75°C (157.55°F),then intake air temperature is 0°C (32°F).
- If engine coolant temperature > 69.75°C (157.55°F), then intake air temperature is 60°C (140°F).
Failure detected on ECTS
- Intake air temperature is 60°C (140°F).
- Short in IATS circuit
- IATS
- ECM

SPECIFICATIONS
IATS
Normal Parameter
20°C (68°F)
40°C (104°F)
80°C (176°F)
Resistance
2.22~2.82 kΩ
1.06~1.31 kΩ
0.29~0.36 kΩ

SCHEMATIC DIAGRAM

SIGNAL WAVEFORM

INSPECTION PROCEDURES