BASIC INSPECTION ITEM
AUTOMATIC TRANSAXLE FLUID CHECK
1.
Drive the vehicle until the fluid temperature rises to the normal temperature (70-80°C).
2.
Park the vehicle on a level surface.
3.
Move the selector lever through all positions to fill the torque converter and the hydraulic circuits with fluid, and then move the selector lever to the N position.
4.
After wiping off any dirt around the oil level gauge(dipstick), remove the oil level gauge and check the condition of the fluid.
If the fluid smells burned, it means that the fluid has been contaminated by fine particles from the bushings and friction materials, a transaxle overhaul may be necessary.
5.
Check that the fluid level is at the HOT mark on the oil level gauge. If the fluid level is lower than this, pour in more fluid until the level reaches the HOT mark. Automatic transmission fluid : DIAMOND ATF SP-III., SK ATF SP-III
If the fluid level is low, the oil pump will draw in air along with the fluid, which will cause bubbles to form inside the hydraulic circuit. This will in turn cause the hydraulic pressure to drop, which will result in late shifting and slipping of the clutches and brakes. If there is too much fluid, the gears can churn it up into foam and cause the same conditions that can occur with low fluid level. In either case, air bubbles can cause overheating and oxidation of the fluid which can interfere with normal valve, clutch, and brake operation. Foaming can also result in fluid escaping from the transmission vent, in which case it may be mistaken for a leak.
6.
Securely insert the oil level gauge.
7.
The fluid and the oil filters should always be replaced when overhauling the transmission or after the vehicle has been driven under severe conditions. The replacement procedures are given below. Furthermore, the oil filters are special filters which are only to be used for the automatic transmission.
When new, automatic transmission fluid should be red. The red dye is added so distinguish it from engine oil or antifreeze. As the vehicle is driven the transmission fluid will begin to look darker. The color may eventually appear light brown.
Also, the dye, which is not an indicator of fluid quality, is not permanent.
Therefore, further investigation of the automatic transaxle is required if,
•
the fluid is dark brown or black.
•
the fluid smells burnt.
•
metal particles can be seen or felt on the dipstick.
AUTOMATIC TRANSMISSION FLUID
REPLACEMENT
Replace the fluid by the following procedure.
1.
Disconnect the hose which connects the transmission and the oil cooler (inside the radiator).
2.
Start the engine and let the fluid drain out.

Running conditions : N range with engine idling.

The engine should be stopped within one minute after it is started. If the fluid has all drained out before then, the engine should be stopped at that point.
3.
Remove the drain plug from the bottom of the transmission case to drain the fluid.
4.
Install the drain plug via the gasket, and tighten it the specified torque.

Tightening torque : 32 Nm

5.
Pour the new fluid in through the oil filler tube.
Stop pouring if the full volume of fluid cannot be poured in.
6.
Repeat the procedure in step (2).
Check the old fluid for contamination. If it has been contaminated, repeat the steps (5) and (6).
7.
Pour the new fluid in through the oil filler tube.
8.
Reconnect the hose which was disconnected in step (1) above, and firmly replace the oil level gauge.
(In case of this "replace", this means after wiping off any dirt around the oil level gauge, insert it into the filler tube.)
9.
Start the engine and run it at idle for 1-2 minutes.
10.
Move the select lever through all positions, and then move it to the N position.
11.
Drive the vehicle until the fluid temperature rises to the normal temperature (70~80°C), and then check the fluid level again. The fluid level must be at the HOT Mark.
12.
Firmly insert the oil level gauge into the oil filler tube.

TRANSAXLE RANGE SWITCH CONTINUITY CHECK

TRANSAXLE RANGE SWITCH AND CONTROL CABLE ADJUSTMENT
1.
Set the selector lever to the "N" position.
2.
Loosen the control cable to manual control lever coupling nut to free the cable and lever.
3.
Set the manual control lever to the neutral position.

4.
Loosen the transaxle range switch body mounting bolts and then turn the transaxle range switch body so the hole in the end of the manual control lever and the hole (cross section A-A in the figure) in the flange of the transaxle range switch body flange are aligned.
5.
Tighten the transaxle range switch body mounting bolts to the specified torque. Make sure at this time that the position of the switch body did not move.

6.
Gently pull the transmission control cable in the direction of the arrow, and then tighten the adjusting nut.
7.
Check that the selector lever is in the "N" position.
8.
Check that each range on the transmission side operates and functions correctly for each position of the selector lever.

A/T CONTROL COMPONENT CHECK
1.
THROTTLE POSITION SENSOR CHECK
The TP Sensor is a variable resistor type that rotates with the throttle body shaft to sense the throttle valve angle. As the throttle shaft rotates, the output voltage of the TP Sensor changes. The ECM detects the throttle valve opening based on voltage change. (Refer to FL-section).

2.
OIL TEMPERATURE SENSOR CHECK

(1)

Remove the oil temperature sensor.

(2)

Measure the resistance between terminals No.1 and No.2 of the oil temperature sensor connector.
STANDARD VALUE
Oil temperature (°C)
Resistance (KΩ)
0
16.7 ~ 20.5
100
0.57 ~ 0.69

3.
VEHICLE SPEED SENSOR CHECK

(1)

Remove the vehicle speed sensor and connect a 3~10KΩ resistance as shown in the illustration.

(2)

Turn the shaft of the vehicle speed sensor and check that there is voltage between terminals 1-2 (1 turn = 4 pulses).

4.
A/T CONTROL RELAY CHECK

(1)

Remove the A/T control relay.

(2)

Use jumper wires to connect A/T control relay terminal (2) to the battery(+) terminal and terminal (4) to the battery(-) terminal.

(3)

Check the continuity between terminal (1) and terminal (3) of the A/T control relay when the jumper wires are connected to and disconnected from the battery.

(4)

If there is a problem, replace the A/T control relay.
Jumper wire
Continuity between terminal No.1
Connected
Continuity
Disconnected
No continuity

5.
SOLENOID VALVE CHECK

(1)

Remove the valve body cover.

(2)

Disconnect the connectors of each solenoid valve.

(3)

Measure the resistance between terminals 1 and 2 of each solenoid valve.
Standard value
Name
Resistance
Damper clutch solenoid valve
2.7 ~ 3.4Ω
(at 20°C)
Low and reverse solenoid valve
Second solenoid valve
Underdrive solenoid valve
Overdrive solenoid valve

(4)

If the resistance is outside the standard value, replace the solenoid valve.
Resistance of the solenoid valve connector.
Terminal No.
Name
Resistance
7 & 10
Damper clutch solenoid valve
2.7 ~ 3.4Ω
(at 20°C)
10 & 6
Low and reverse solenoid valve
9 & 4
Second solenoid valve
9 & 3
Underdrive solenoid valve
9 & 5
Overdrive solenoid valve

TORQUE CONVERTER STALL TEST
This test measures the maximum engine speed when the selector lever is at the D or R position and the torque converter stalls to test the operation of the torque converter, and one-way clutch operation and the holding performance of the clutches and brakes in the transmission.
Do not let anybody stand in front of or behind the vehicle while this test is being carried out.
1.
Check the automatic transmission fluid level and temperature and the engine coolant temperature.
A.
Fluid level : At the HOT mark on the oil level gauge
B.
Fluid temperature : 80~100°C
C.
Engine coolant temperature : 80~100°C
2.
Check wheels.
3.
Pull the parking brake lever on, with the brake pedal fully depressed.
4.
Start the engine.
5.
Move the selector lever to the D position, fully depress the accelerator pedal and take a reading of the maximum engine speed at this time.
1)
The throttle should not be left fully open for any more than eight seconds.
2)
If carrying out the stall test two or more times, move the selector lever to the N position and run the engine at 1,000 r/min to let the automatic transaxle fluid cool down before carrying out subsequent tests.

Standard value
Stall speed : 2,000 ~ 2,900r/min

3)
Move the selector lever to the R position and carry out the same test again.

Standard value
Stall speed : 2,000 ~ 2,900r/min

TORQUE CONVERTER STALL TEST JUDGEMENT RESULTS
1.
Stall speed is too high in both D and R ranges
A.
Low line pressure
B.
Low & reverse brake slippage
2.
Stall speed is too high in D range only
A.
Underdrive clutch slippage
3.
Stall speed is too high in R range only
A.
Reverse clutch slippage
4.
Stall speed too low in both D and R ranges
A.
Malfunction of torque converter
B.
Insufficient engine output

HYDRAULIC PRESSURE TEST
1.
Warm up the engine until the automatic transaxle fluid temperature is 80 ~ 100°C.
2.
Jack up the vehicle so that the wheels are free to turn.
3.
Connect the special tools oil pressure gauge to each pressure discharge port.
4.
Measure the hydraulic pressure at each port under the conditions given in the standard hydraulic pressure table, and check that the measured values are within the standard value ranges.
5.
If a value is outside the standard range, correct the problem while referring to the hydraulic pressure test diagnosis table.

STANDARD HYDRAULIC PRESSURE TEST
Measurement condition
Standard hydraulic pressure kPa (psi)
Selector lever position
Shift position
Engine speed (rpm)
Under drive clutch pressure
Reverse clutch pressure
Overdrive clutch pressure
Low and reverse brake pressure
Second brake pressure
Torque converter pressure
P
-
2,500
-
-
-
310 ~ 390 (45 ~ 56)
-
250 ~ 350 (36 ~ 56)
R
Reverse
2,500
-
1,270 ~ 1,770 (185 ~ 256)
-
1,270 ~ 1,770 (185 ~ 256)
-
500 ~ 700 (73 ~ 101)
N
2,500
-
-
-
-
310 ~ 390 (45 ~ 56)
-
250 ~ 390 (36 ~ 56)
D
1st gear
2,500
1,010 ~ 1,050 (146 ~ 152)
-
-
*1,010 ~ 1,050 (146 ~ 152)
-
500 ~ 700 (73 ~ 101)
2nd gear
2,500
1,010 ~ 1,050 (146 ~ 152)
-
-
-
1,010 ~ 1,050 (146 ~ 152)
500 ~ 700 (73 ~ 101)
3rd gear
2,500
590 ~ 690 (85 ~ 100)
-
590 ~ 690 (85 ~ 100)
-
-
450 ~ 650 (65 ~ 94)
4th gear
2,500
-
-
590 ~ 690 (85 ~ 100)
-
590 ~ 690 (85 ~ 100)
450 ~ 650 (65 ~ 94)

OIL SEAL LOCATION

HYDRAULIC PRESSURE TEST DIAGNOSIS TABLE
Trouble symptom
Probable cause
All hydraulic pressures are high
Incorrect transmission control cable adjustment
Malfunction of the regulator valve
All hydraulic pressures are low
Incorrect transmission control cable adjustment
Malfunction of the oil pump
Clogged oil filter
Clogged oil cooler
Malfunction of the regulator valve
Malfunction of the relief valve
Incorrect valve body installation
Hydraulic pressure is abnormal in "R" range only
Malfunction of the regulator valve
Clogged orifice
Incorrect valve body installation
Hydraulic pressure is abnormal in "3" or "4" range only
Malfunction of the regulator valve
Clogged orifice
Incorrect valve body installation
Malfunction of the overdrive solenoid valve
Malfunction of the overdrive pressure control valve
Malfunction of the regulator valve
Malfunction of the switch valve
Clogged orifice
Incorrect valve body installation
Only underdrive hydraulic pressure is abnormal
Malfunction of the oil seal K
Malfunction of the oil seal L
Malfunction of the oil seal M
Malfunction of the underdrive solenoid valve
Malfunction of the underdrive pressure control valve
Malfunction of check ball
Clogged orifice
Incorrect valve body installation
Only reverse clutch hydraulic pressure is abnormal
Malfunction of the oil seal A
Malfunction of the oil seal B
Malfunction of the oil seal C
Clogged orifice
Incorrect valve body installation
Only overdrive hydraulic pressure is abnormal
Malfunction of the oil seal D
Malfunction of the oil seal E
Malfunction of the oil seal F
Malfunction of the overdrive solenoid valve
Malfunction of the overdrive pressure control valve
Malfunction check ball
Clogged orifice
Incorrect valve body installation
Only low and reverse hydraulic pressure is abnormal
Malfunction of the oil seal I
Malfunction of the oil seal J
Malfunction of the low and reverse solenoid valve
Malfunction of the low and reverse pressure control valve
Malfunction of the switch valve
Malfunction of the fail safe valve A
Malfunction of check ball
Clogged orifice
Incorrect valve body installation
Only second hydraulic pressure is abnormal
Malfunction of the oil seal G
Malfunction of the oil seal H
Malfunction of the oil seal O
Malfunction of the second solenoid valve
Malfunction of the second pressure control valve
Malfunction of the fail safe valve B
Clogged orifice
Incorrect valve body installation
Only reverse clutch hydraulic pressure is abnormal
Malfunction of the oil cooler
Malfunction of the oil seal N
Malfunction of the damper clutch control solenoid valve
Malfunction of the damper clutch control valve
Malfunction of the torque converter pressure control valve
Clogged orifice
Pressure applied to non operating element
Incorrect valve body installation
Incorrect transmission control cable adjustment
Malfunction of the manual valve
Malfunction of check ball
Incorrect valve body installation

HYDRAULIC CONTROL SYSTEM
DESCRIPTION
1.
The hydraulic control system consists of the following components :

(1)

Oil pump : Generates the hydraulic pressure.

(2)

Regulator : Maintains the hydraulic pressure at a constant level.

(3)

Solenoid valves : Convert TCM signals to hydraulic pressure.

(4)

Pressure control valve : Controls the hydraulic pressure acting on the clutches and brakes according to the hydraulic pressure from the solenoid valves.

(5)

Individual valves : Direct line pressure to the various oil lines.
These components are all housed in the valve body.
2.
Independent electronic control of the hydraulic pressure from the clutch and brake solenoid valves realizes smooth and highly responsive gear shifts.
3.
Oil filter is provided in one place.
Also, the use of a newly developed automatic transaxle fluid (ATF) ensures a longer ATF service life.
4.
To prevent the escape of ATF from the valve body, clutches and brakes when the engine is not running, the valve drainage ports are connected to a single drainage port that is located at a high point on the casing, and a ball check valve is fitted at the end of the drainage line.
5.
In the event of an electronic control system fault, a switch valve and fail-safe valve arrangement enables operation in 3rd gear or reverse.