The Full Automatic
Temperature Control (F.A.T.C) module self test feature will detect
electrical malfunctions and provide error code for system components with
suspected failures.
CONTROL PANEL

SELF-DIAGNOSIS HETHOD

HOW TO READ SELF-DIAGNOSTIC CODE
| 1. |
After the display panel flickers three times
every 0.5 second, the corresponding error code flickers on the setup
temperature display panel every 0.5 second and will show two
figures. |
| 2. |
If error code is more than two, each code
flicker 2 times in sequence.

|
FAULT CODE DISPLAY
| 1. |
Normal

|
| 2. |
One error code

|
| 3. |
More error codes than two

|
| 4. |
Checking each error code

|
DTC CHART
|
If malfunction code is displayed during the
DTC check, check the circuit listed for that code in the table
below. |
|
DTC
code |
Detection
item |
Trouble
area |
|
00 |
Normal |
- |
|
11 |
Open INCAR Sensor circuit |
| •
|
Harness or connector between incar
sensor and A/C control
assembly |
|
|
12 |
Shorted INCAR Sensor
circuit |
|
13 |
Open Ambient sensor circuit |
| •
|
Harness or connector between ambient
sensor and A/C control
assembly |
|
|
14 |
Shorted Ambient sensor
circuit |
|
15 |
Open water temp. sensor |
| •
|
Harness or connector between water temp.
sensor and A/C control
assembly |
|
|
16 |
Shorted water temp. sensor |
|
17 |
Open thermistor |
| •
|
Harness or connector between evap.
sensor and A/C control
assembly |
|
|
18 |
Shorted thermistor |
|
19 |
Open or shorted temp. door
potentiometer |
| •
|
Harness or connector between temp. door
potentiometer and A/C control
assembly | |
|
20 |
Defective temp. door
potentiometer |
| •
|
Temp. door
potentiometer | |
|
21 |
Open or shorted mode door
potentiometer |
| •
|
Harness or connector between mode door
potentiometer and A/C control
assembly | |
|
22 |
Defective mode door
potentiometer |
| •
|
Mode door
potentiometer | |
FAIL SAFE FUNCTION
|
No. |
Item |
Failure |
FAIL SAFE
Function |
|
1 |
IN-CAR temperature sensor |
Open/Short |
25°C alternate value
control |
|
2 |
Ambient temperature sensor |
Open/Short |
20°C alternate value
control |
|
3 |
Thermistor sensor |
Open/Short |
-2°C alternate value
control |
|
4 |
Water temperature sensor |
Open/Short |
-20°C alternate value
control |
|
5 |
Temperature door potentiometer |
Open/Short setup temperature |
For 17°C to 24.5°C, set to maximum cooling
position.
For 25°C to 32°C, set to maximum heating
position. |
|
6 |
Mode door potentimeter |
Open/Short setup mode |
Vent mode, at vent mode
Def mode, at except vent
mode |