The triple pressure
switch is a combination of the low pressure switch (for checking the
quantity of refrigerant) and the high pressure switch (for prevention of
air conditioning line burst) and medium pressure switch (for cooling fan
operation). It is installed in the receiver drier and , when the pressure
becomes approximately 200 kPa (29 psi) or lower, the compressor stops,
thus preventing the compressor from being damaged by sticking. When the
pressure reaches 1,800 kPa (261 psi)or higher, the cooling fans run high
speed from low speed, thus preventing the power consumption of cooling
fans from being discharged. When the pressure reaches 3,241 kPa (470 psi)
or higher, the compressor stops, thus preventing air conditioning line
burst. There is generally no necessity for inspection; if, however, an
unusual condition, such as nonoperation of the compressor is encountered,
check by following the procedures below.
|