The water temp. sensor
is wired to the temp. actuator potentiometer and attached to the heater
core inlet tube under the actuator mounting bracket with a spring tension
clip. The two leads to the clip start in the wire and connector assembly
which feeds into the electronically controlled blend door actuator. It
automatically prevents the blowing out of cold air at a high flow rate
when the outside air temperature is low when the engine is not warmed up.
This control is provided only when the blower switch is in the AUTO range.
Until the engine coolant temperature reaches approximately 50°C (122°F) or
the desired temperature becomes equal or more than inside temperature
+3°C, cold air will not blow inside and fan speed is at low mode. In the
MANUAL mode, the speed is in accordance with the range setting, and the
fan control at low and warm coolant temperature does not
work.
CHECKING THE OPERATION OF WATER TEMP.
SENSOR
| 1. |
Immerse the water temp. sensor in
water. |
| 2. |
Using a stove, heating the water measure the
resistance between terminal 1 and terminal 2.
Check the resistance value is within
specification as shown in the graph.
|
Water
temperature |
Resistance |
|
25°C |
12.5 ± 0.5kΩ |
|
69°C |
2.5 ±
0.3kΩ |

|