BURGLAR ALARM SYSTEM
The burglar
alarm system is armed automatically after the doors, hood, and trunk are
closed and locked.
The system is set off
when any of these things occur :
| • |
A door is unlocked without using the
transmitter. |
| • |
The trunk lid is opened without using the key
or the transmitter. |
| • |
The engine starter circuit and battery circuit
are bypassed by breaking the ignition
switch. |
When the
system is set off, the alarm (siren) sounds and the hazard lamp flash for
about two minutes or until the system is disarmed by unlocking the
transmitter.
For the system
to arm, the ignition switch must be off and the key removed. Then, the
ETACS module must receive signals that the doors, hood, and trunk lid are
closed and locked. When everything is closed and locked, none of the
control unit inputs are grounded.
The door
switches, hood switch and trunk lid switch are all open then immediately
after locking the doors with the remote transmitter the system arms.
If anything is
opened or improperly unlocked after the system is armed, the ETACS module
gets a ground signal from that switch, and the system is set off.
If the trunk
is opened using the key after the system is armed, the doors and hood are
continues arm state and the system will be not set off. Then after the
trunk is closed, the trunk hold arm state.
If one of the
switches is misadjusted or there is a short in the system, the system will
not arm. As long as the ETACS module continues to get a ground signal, it
thinks the vehicle is not closed and locked and will not arm.
An alarm that
sounds for no apparent reason may have been set off by a switch that is on
the threshold of misadjustment. In this case, it may only take a
significant change in outside temperature, the vibration of a passing
truck, or someone bumping into the vehicle to make the alarm sound.
KEYLESS ENTRY SYSTEM
The burglar
alarm system is integrated with the keyless entry system. The keyless
entry system allows you to lock and unlock the vehicle with the remote
transmitter.When you push the LOCK button, all doors lock. When you push
the UNLOCK button all doors unlock.
The room lamp,
if its switch is in the center position, will come on when you press the
UNLOCK button. If you do not open a door, the light will go off in about
30 seconds, the doors will automatically relock, and the burglar alarm
system will rearm. If you relock the doors with the remote transmitter
within 30 seconds, the light will go off immediately.
You cannot
lock or unlock the doors with the remote transmitter if the key is in the
ignition switch.
To open the
trunk, push the trunk open button on the transmitter and hold it for about
two seconds.
The system
will signal you when the doors lock and unlock by flashing the hazard lamp
once when they lock, and twice when they unlock.
| 1. |
ARM
FUNCTION
Pressing the remote key lock button will
result in a 0.5-second pulse issued to lock all doors.
Pressing the remote keypad unlock button once
will result in a 0.5-second unlock pulse issued to unlock all
doors.
As part of the arming sequence the alarm first
enters a pre-armed state before falling into the armed state. During
this pre-armed state alarm triggers are ignored. Pre-armed state can
be reached from the alarmed state, the start inhibit state or the
disarmed state. Pre-Arming of the alarm can be achieved by a press
of the lock button on the remote key.
In the pre-armed state the visible and audible
warnings are disabled.
This system enters the armed state if it is in
the pre-armed state and,after 0.6 sec, check actuator lock and each
door, hood and trunk close,and no door warning switch (no key in
ignition).
On entering the arm state, a single flash of
the hazard lamps is given,period of cycle 2 second, duty rate
50%.
If transmitter(TX) lock signal is received
when a door, trunk or hood is open,then lock output is given and a
flash of hazard is not given.
After the armed state is entered, if a lock
signal is received then a single flash of the hazard lamps is given,
period of cycle 2 second, duty rate 50%.
The armed state cannot be reached by locking
the car with the keys.

Time specification
T1 : 0.5 ± 0.1 sec.
T2 : Max. 2 sec.
T3 : 1.0 ± 0.2
sec. |
| 2. |
DISARM
FUNCTION
Disarming can be performed while the alarm is
armed, or alarming, or after alarming. The alarm can be disarmed by
the following methods :
| A. |
Pressing the unlock button on the
transmitter(TX) key. The hazard lamps shall be flashed twice
for 1sec period (of cycle), 50% duty
rate. |
| B. |
If door warning switch is on, IGN1 and
IGN2 are on in arm state,then arm state should be immediately
cancelled. This means that the driver is inside the vehicle
before pushing TX lock, so system should not
arm. |
In the disarm state the visible and audible
warnings are disabled and start is enabled.
In the disarm state, if TX key unlock command
is received, then the hazard lamps shall be flashed twice for period
of cycle 1 sec, 50% duty rate.

Time specification
T1, T2 : 0.5 ± 0.1
sec. |
| 3. |
ALARM
FUNCTION
Once armed, should any door, hood or the trunk
be opened, then.
| A. |
Start relay drive output is disabled, so
starting is inhibited. |
| B. |
Audible (siren) and visual (hazard lamp)
warnings are issued, for three cycles, each cycle 27±2 sec.
duration on, 10±1 sec. off. The siren warning is continuously
occurring during the on period. The hazard lamps operate with
1 sec period, 50 % duty rate during the on
period. |
The alarm is given in the case where a door is
opened with a key.
After this time, the system maintains the
start inhibit state, where no audible and visual warnings are issued
but engine starting is not possible.

Time specification
T1 : 27 ± 2 sec.
T2 : 10 ± 1sec.
T3 : 0.5 ± 0.1
sec. |
| 4. |
OPERATION DURING
ALARM CONDITIONS
|
(1) |
Cancelling audible alarm with the remote
transmitter.
CASE 1 : Door
closed
During or after alarming and then
closing all doors and a transmitter (TX) lock signal is
received Then
| -
|
The lock command is executed with
0.5 sec. ON |
| -
|
Siren and start inhibition are
OFF |
| -
|
Hazard lamp is flashed one time
(period : 2 sec., duty: 50%, within2
sec.) |
| -
|
The state goes to arming mode
(after a lock state
check) |
| -
|
The start is enabled

|
Time specification
T1 : 0.5 sec.
T2 : 1.0 ± 0.2 sec.
CASE 2 : Door
Open
During or after alarming, with a door
open and a TX lock signal is received Then
| -
|
The lock command is executed with
0.5 sec. ON |
| -
|
Siren is disabled and start is
enabled after confirmation of actuator
lock |
At this time, when the door is
closed,
| -
|
Hazard lamp is flashed one time
(period : 2 sec., duty
50%) |
| -
|
The state goes to arming
mode

|
Time specification
T1 : 0.5 sec.
T2 : 1.0 ± 0.2
sec. |
|
(2) |
New alarm conditions
Second alarm condition during
alarming.
When another alarm occurs during
alarming, the starting is disabled,and the alarm continues to
sound for the remained time of warning signal.The alarm
continues to sound after the second alarm condition is
removed.
New alarm condition occurs after
alarming (with all entrances closed)
If any entrance is opened again
then
| -
|
The siren is ON 3
times |
| -
|
Hazard lamps flash during the ON
time of siren |
New alarm condition occur after alarming
(with any entrance open).
If another entrance is opened, the ETACS
module keeps start disabled and there is no siren
output.

|
|
(3) |
Key operation during alarm
After the alarm state or start inhibit
state are entered, if door warning switch on (key in ignition)
&IGN 2 ON, if IGN 2 state is changed to OFF within 30sec.,
remain in alarm state. |
|
(4) |
Disarming using the key
During alarming, in case that door
warning switch (key in) is ON and then IGN1 and IGN2 are both
ON for 30 sec continuously, the alarm is cancelled,and the
system enters the disarm state.
After alarming, in case that door
warning switch (key in) is ON and then IGN1 and IGN2 are both
ON for 30 sec continuously, the alarm is cancelled,and the
system enters the disarm state.

| |
| 5. |
ALARM STATE IN POWER
DOWN
If the battery is disconnected to the ETACS
module in the following states :
Upon restoring the battery, the alarm state
shall be entered and the alarm cycle shall restarted (timer reset to
0).

|
| 6. |
ALARM HOLD
MODE
|
(1) |
In case of opening the trunk by trunk
unlock switch during arm state, the alarming is
hold.
When received transmitter (TX) trunk
signal in arm state, trunk open by output trunk lid open relay
signal for 500ms and then holding alarm.
But the door and hood except trunk is
still in the arm state. |
|
(2) |
Trunk is going to the arm state just
case trunk is still closed for 2 sec.

T1 : Max. 0.2 sec., T2 : 2
sec. | |