| 1. |
Check for a burnt relay with an
ohmmeter. |
| 2. |
If a relay burns out, there is a short or some
other problem in the circuit. Carefully determine the cause and
correct it before replacing therelay.

|
INSPECTION OF FUSES
When a fuse is
blown, there are two probable causes. The two causes can easily be
determined by a visual check after removing the fuses.
| 1. |
Fuse blown due to
over-current
Prior to replacing the fuse with a new one,
check the circuit for a short and the related parts for abnormal
conditions.
Only after the correction of a short or
replacement of abnormal parts, should a fuse with the same
ampererating be installed.

|
| 2. |
Fuse blown due to
repeated on-off current
Normally, this type of problem occurs after a
fairly long period of use, and is less frequent than #1 above. In
this case, you may simply replacewith a new fuse of the same
capacity.

|
A blade type fuse is identified by the
numbered value in amperes. If the fuse is blown, be sure to
replace a fuse with the same ampere rating. If a fuse of
higher capacity than specified is used, parts may be damaged
and a danger of fire exists. To remove or insert a fuse, use
the fuse pullerin the fuse box.

| |