Home › Fuel System › Troubleshooting

P0030 HO2S Heater Control Circuit (Bank 1, Sensor 1)

SIEMENS EMS
DIAGNOSTIC ITEM
DTC
P0030
O2 Sensor Heater Control Circuit (Bank1, Sensor1)

DESCRIPTION
In order to control emissions of the CO, HC and NOx components of the exhaust gas, heated oxygen sensor (HO2S), mounted on the front side and rear side of catalytic converter, detects the oxygen content in the exhaust gas. The front HO2S signal is used to control air/fuel ratio (closed loop fuel control) and the rear HO2S signal is used to monitor front HO2S and catalyst for proper operation.The HO2S requires a minimum temperature to operate properly and provide a closed loop fuel control system. So HO2S contains the heater element to reduce its warming-up time and ensure its performance during all driving conditions, which can operate closed loop fuel control or catalyst monitoring immediately upon engine start-up.The ECM controls this heater element by duty cycle. The main relay supplies voltage to the heater and the ECM provides a ground circuit for activating the heater.
DTC DETECTING CONDITION
DTC No
Detecting Condition & Limp Home
Suspect area
P0030
Detecting Condition
The HO2S heater duty is not consistent with the tip temperature of HO2S.
Enable Condition
- Vehicle speed < 80 km/h
- 640 RPM < engine speed < 2500 RPM
- 80 mg/stroke < mass air flow < 250 mg/stroke
Limp Home
None
- Open or short in front HO2S heater circuit
- Front HO2S heater
- ECM

SPECIFICATIONS
HO2S Heater
Normal Parameter
18 ~ 28°C (64 ~ 82°F)
Heater Resistance
3 ~ 4Ω

SCHEMATIC DIAGRAM

SIGNAL WAVEFORM

INSPECTION PROCEDURES