DESCRIPTION
The heated
oxygen sensor is mounted on the front side of Catalytic Converter (warm-up
catalytic converter) or in the front exhaust pipe, which detects the
oxygen concentration in the exhaust gas. The heated oxygen sensor (HO2S)
produces a voltage that varies between 0V and 1V. When the air/fuel ratio
is lean, the oxygen concentration in the exhaust gas increases and the
front HO2S outputs a low voltage (approximately 0 ~ 0.1V). When the
air/fuel ratio is rich, the oxygen concentration in the exhaust gas
decreases and the front HO2S outputs a high voltage (approximately 0.8 ~
1V). The ECM constantly monitors the HO2S and increases or decreases the
fuel injection duration by using the HO2S signal, which is called
closed-loop fuel control operation.
DTC DETECTING CONDITION
SPECIFICATIONS
SCHEMATIC DIAGRAM
SIGNAL WAVEFORM
INSPECTION PROCEDURES
| ||||||||||||||||||