Home › Fuel System › Troubleshooting

P0150 O2 Sensor Circuit Malfunction (Bank2, Sensor1)

p
DTC
P0150
O2 Sensor Circuit Malfunction (Bank2, Sensor1)

DESCRIPTION
The heated oxygen sensor is mounted on the front side of Catalytic Converter (warm-up catalytic converter) or in the front exhaust pipe, which detects the oxygen concentration in the exhaust gas. The heated oxygen sensor (HO2S) produces a voltage that varies between 0V and 1V. When the air/fuel ratio is lean, the oxygen concentration in the exhaust gas increases and the front HO2S outputs a low voltage (approximately 0 ~ 0.1V). When the air/fuel ratio is rich, the oxygen concentration in the exhaust gas decreases and the front HO2S outputs a high voltage (approximately 0.8 ~ 1V). The ECM constantly monitors the HO2S and increases or decreases the fuel injection duration by using the HO2S signal, which is called closed-loop fuel control operation.
DTC DETECTING CONDITION
DTC No
Detecting Condition & Limp Home
Suspect area
P0150
Detecting Condition
0.36V < HO2S signal < 0.49V
Enable Condition
- Sensor pre-heating and full heating phases finished
- Lambda control active
- No relevant failure
- Battery voltage > 10V
Limp Home
None
- Open in HO2S circuit
- Front HO2S
- ECM

SPECIFICATIONS
HO2S
Normal Parameter (at 1300 rpm after warming up)
Signal voltage
Rich
Lean
0.6 ~ 1.0 V
0 ~ 0.4 V

SCHEMATIC DIAGRAM

SIGNAL WAVEFORM

INSPECTION PROCEDURES