Self-diagnosis
process
The F.A.T.C. module
self test feature will detect electrical malfunction and provide error
codes for system components with suspected failures.

|
Turn off the A/C system during the DTC
check. |
HOW
TO READ SELF-DIAGNOSTIC CODE
| 1. |
After the display panel flickers three times
every 0.5 second, the corresponding fault code flickers on the setup
temperature display panel every 0.5 second and will show two
figures. |
| 2. |
Fault code
Fault code
|
Fail
description
|
Control
unit
|
Scan
tool (DTC)
|
00
|
-
|
Normal
|
11
|
B1234
|
In-car temperature sensor open
(High)
|
12
|
B1233
|
In-car temperature sensor short
(Low)
|
13
|
B1238
|
Ambient temperature sensor open
(High)
|
14
|
B1237
|
Ambient temperature sensor short
(Low)
|
15
|
B1202
|
Water temperature sensor open
(High)
|
16
|
B1203
|
Water temperature sensor short
(Low)
|
17
|
B1242
|
Evaporator temperature sensor open
(High)
|
18
|
B1241
|
Evaporator temperature sensor short
(Low)
|
19
|
B1245
|
Air mix potentiometer open (Low) -
Driver
|
19
|
B1246
|
Air mix potentiometer short (High) -
Driver
|
20
|
B2406
|
Air mix motor failure (Driver)
|
21
|
B1249
|
Direction potentiometer open (Low) -
Driver
|
21
|
B1250
|
Direction potentiometer short (High) -
Driver
|
22
|
B2409
|
Direction control motor failure
(Driver)
|
23
|
B1200
|
Humidity sensor open (High)
|
24
|
B1201
|
Humidity sensor short (Low)
|
25
|
B1208
|
Intake potentiometer open (Low)
|
25
|
B1209
|
Intake potentiometer short
(High)
|
26
|
B2408
|
Intake motor failure
|
27
|
B1257
|
AQS sensor open (High)
|
28
|
B1258
|
AQS sensor short (Low)
|
29
|
B1259
|
AQS sensor
failure
|
|
| 3. |
Fault code display
| (1) |
Continuance operation

|
| (2) |
Step operation

| |
| 4. |
If a fault code is displayed during the DTC
check, Inspect a malfunction cause by referring to the DTC
code. |
| 5. |
Fail safe
| (1) |
In-car temperature sensor: Control
with the value of 25°C(77°F) |
| (2) |
Ambient temperature sensor: Control
with the value of 20°C(67°F) |
| (3) |
Evaporator temperature sensor: Control
with the value of
-2°C(28.4°F) |
| (4) |
Humidity sensor: Control with the
value of 10% |
| (5) |
Temperature sensor : Control with the
value of -2°C (28.4°F) |
| (6) |
Temperature control actuator (Air mix
potentiometer):
If temperature setting 17°C-24.5°C,
fix at maximum cooling position.
If temperature setting 25°C-32°C, fix
at maximum heating position. |
| (7) |
Mode control actuator (Direction
potentiometer):
Fix vent position, while selecting
vent mode.
Fix defrost position, while selecting
all except vent mode. |
| (8) |
Intake control actuator :
Fix fresh position, while selecting
fresh mode.
Fix recirculation position, while
selecting recirculation mode. |
| (9) |
AQS sensor : AQS operation
OFF.
| A. |
Intake position : The position
before selecting AQS
switch. | | |
| 1. |
Disconnect the negative (-) battery
terminal. |
| 2. |
Remove the center facia panel (A) after
pulling it by using a regular screw driver (-).

|
| 3. |
Disconnect the connectors (B) from the
center facia.

|
| 4. |
Remove the heater & A/C controller
(C).

|
| 5. |
Install in the reverse order of
removal. |