HAZARD
LAMP
Check for continuity
between the terminals.
| 1. |
There should be continuity between the No.12
and No.13 terminals when power and ground are connected to the No.13
and No.3 in the M91-2 terminals. |
| 2. |
There should be no continuity between the
No12 and No.13 terminals when power is
disconnected. |
BURGLAR
ALARM HORN
Check for continuity
between the terminals.
| 1. |
There should be continuity between the No.8
and No.9 terminals when power and ground are connected to the No.1
and No.8 in the M91-2 terminals. |
| 2. |
There should be no continuity between the
No.8 and No.9 terminals when power is
disconnected. |
BURGLAR
ALARM
Check for continuity
between the terminals.
| 1. |
There should be no continuity between the
No.11 and No.10 terminals when power and ground are connected to the
No.11 and No.4 in the M91-2
terminals. |
| 2. |
There should be continuity between the No.11
and No.10 terminals when power is
disconnected. |
ADJUST
PEDAL
Check for continuity
between the terminals.
| 1. |
There should be continuity between the No.15
and No.5 terminals when power and ground are connected to the No.15
and No.2 in the M91-2 terminals. |
| 2. |
There should be no continuity between the
No.15 and No.5 terminals when power is
disconnected. |
DRIVER
DOOR TWO TURN UNLOCK
Check for continuity
between the terminals.
| 1. |
There should be continuity between the No.7
and No.4 terminals when power and ground are connected to the No.6
and No.4 in the M91-1 terminals. |
| 2. |
There should be continuity between the No.7
and No.5 terminals when power and ground are
disconnected. |