Home › Brake System › Troubleshooting

C1235 Enable Conditions

COMPONENT LOCATION

GENERAL DESCRIPTION
The pressure sensor senses the brake oil pressure to judge driver's brake intention when ESC is operating.
DTC DETECTING CONDITION
Item
Detecting Condition
Possible cause
DTC Strategy
Signal monitoring

•
Faulty HECU
C1235
Enable Conditions

1.
Sensor supply voltage is continuous monitored (except power on). A sensor supply failure is detected if Sensor Supply Voltage > 5.3 V OR Sensor Supply Voltage < 4.7 V for t ≥ 60 ms.
2.
Pressure signal 1 (DSO: original pressure value) is continuous monitored (except power on). Line faults like open, short to GND or short to UZ are detected. A Fault is set if the DSO signal is U DSO > 4.7 V OR U DSO < 0.3 V for a time t >= 100 ms.
3.
Pressure signal 2 (DSI: inverted pressure value) is continuous monitored (except power on). Line faults like open, short to GND or short to UZ are detected. A Fault is set if the DSI signal isU DSI > 4.7 V OR U DSI < 0.3 V for a time t >= 100 ms.
4.
Plausibility of DSO and DSI pressure lines are continuous monitored.Internal DS5 faults (amplification-, bridge-, analog-digital converter malfunction, etc.) are detected if DSO+DSI < 4.5 V OR DSO+DSI > 5.5 V is present longer than t >= 100 ms .
5.
POS(Power On Selftest) detects internal sensor malfunctions. sensor element, amplification, etc.) The test phase is divided in two 60 ms parts. DSO signal must be <0.5 V for 30 ms. In phase 2 DSO signal must be between 1.9 V and 3.1V for also 30 ms then the POS Test is passed.
The test phase is divided in two 60 ms parts. DSO and DSI signal must be < 0.5 V for 30 ms. In phase 2 DSO and DSI signal must be between 1.9 V and 3.1 V for also 30 ms then the POS Test is passed.
Monitoring period
1~4 : Continuous
5 : Once during Power Up
C1237
Enable Conditions

1.
The DS(Pressure sensor)-offset value must be in the range of 15 bar. A failure is detected if this range is exceeded.
2.
There are three monitoring which have different thresholds concerning the allowed pressure and the detection time.
1)
Plausibility 1 :
For redundancy reasons an additional hardware-BLS-signal is created by the pressure sensor signal.
If the pressure sensor is compensated, the threshold for generating the hardware-BLS or signal is 10 bar.
If the pressure sensor is not compensated, the threshold is increased by 15 bar.
If this signal is set without any hardware-BLS-signals being set, and if no pump is operated during that time, a fault is set after the braking.
2)
Plausibility 2 :
If the pressure signal is higher than 30 bar and not both of the hardware-BLS are set, a fault is stored after 2s.
3)
Plausibility 3:
If the pressure signal is higher than 80 bar and not both of the hardware-BLS are set, a fault is stored after 1s.
Monitoring period

1.
After DS-initialization, no under voltage, no pumps are running and no BLS-signal is set.
2.
Continuous in the normal operating voltage range.
Effect
No Pressure Signal available.

COMPONENT INSPECTION
1.
Ignition "OFF".
2.
Engine "ON".
Does warning lamp remain On?

▶ Substitute with a known-good HECU and check for proper operation. If problem is corrected, replace HECU and then go to "Verification of Vehicle Repair" procedure.

▶ Fault is intermittent caused by faulty HECU or was repaired and HECU memory was not cleared. Go to the applicable troubleshooting procedure.
VERIFICATION OF VEHICLE REPAIR
After a repair, it is essential to verify that the fault has been corrected..
1.
Connect scantool and select "Diagnostic Trouble Codes(DTCs)" mode.
2.
Using a scantool, Clear DTC.
3.
Operate the vehicle within DTC Detecting Condition in General Information.
Are any DTCs present?

▶ Go to the applicable troubleshooting procedure.

▶ System performing to specification at this time.