As monitoring the errors
of several sensors and actuators circuit,if any problem occurs, PCM turns
engine check lamp ON at cluster to notify driver occurence of a
problem.Generally, engine check lamp turns ON at Ignition ON and turns OFF
within couple of seconds after turning engine ON. If engine check lamp
turns on during driving, perform diagnosis of engine system and
auto-transaxle system.
Checking input signal of
engine check lamp every 10 sec. under detecting condition, if open, or
short to battery or ground is detected for more than 5 sec., PCM sets
P0650.
Item
|
Detecting
Condition
|
Possible cause
|
DTC Strategy
|
|
| •
|
Open or short in MIL
circuit |
|
Enable Conditions
|
| •
|
After 0.5 sec under conditions
below |
| •
|
11V ≤ Battery voltage ≤
16V | |
Threshold value
|
|
Diagnosis Time
|
| •
|
Continuous
(More than 5 seconds failure for every
10 seconds test) | |
MIL On Condition
|
|

| 1. |
IG "OFF" & connect
scantool. |
| 2. |
ENG "ON" and warm -up the engine to normal
operating temperature. |
| 3. |
Compare "Current data" on scantool with
"Engine Warning Lamp" on cluster.

|
| 4. |
Is the current data displayed correctly
?

▶ Fault is intermittent caused by poor contact
in Sensor’s and/or PCM’s connector or was repairedand PCM memory was
not cleared. Thoroughly check connectors for looseness, poor
connection,bending, corrosion, contamination, deterioration, or
damage. Repair or replace as necessary and goto "Verification of
Vehicle Repair" procedure

▶ Go to "Terminal and Connector Inspection"
procedure. |
| TERMINAL AND CONNECTOR
INSPECTION |
| 1. |
Many malfunctions in the electrical system are
caused by poor harness and terminals. Faults can also be caused by
interference from other electrical systems, and mechanical or
chemical damage. |
| 2. |
Thoroughly check connectors for looseness,
poor connection, bending, corrosion, contamination, deterioration,
or damage. |
| 3. |
Has a problem been found?

▶ Repair as necessary and go to "Verification
of Vehicle Repair" procedure

▶ Go to " Power Circuit Inspection "
procedure. |
| 1. |
IG "OFF" and disconnect Instrument cluster
connector. |
| 3. |
Measure voltage between terminal 1 of
instrument cluster harness connector and chassis
ground.
Specification : Approx.
B+
|

|
| 4. |
Is the measured voltage within
specification?

▶ Go to "Control Circuit Inspection"
procedure.

▶ Check fuse between battery and instrument
cluster for open or blown-off.
▶ Repair open or short to ground in harness,
and go to "Verification of Vehicle Repair"
procedure. |
| CONTROL CIRCUIT
INSPECTION |
| 1. |
IG "OFF" and disconnect PCM
connector. |
| 3. |
Measure voltage between 63 of PCM harness
connector and chassis ground.
Specification : Approx.
B+
|

|
| 4. |
Is the measured voltage within
specification?

▶ Go to "Component Inspection"
procedure.

▶ Check open in Engine warning lamp's
filament.
▶ Repair open or short to ground in harness,
and go to "Verification of Vehicle Repair"
procedure. |
| 1. |
Check instrument cluster
| (2) |
Substitute with a known - good
instrument cluster and check for proper
operation. |
| (3) |
Does it normally operate after
replacement?

▶ Replace instrument cluster and go to
"Verification of Vehicle Repair" procedure.

▶ Substitute with a known - good PCM and
check for proper operation. If the problem is corrected,
replace PCM and go to "Verification of Vehicle Repair"
procedure.
|
There is a memory reset function
on scantool that can erase optional parts automatically
detected and memorized by PCM. After testing PCM on the
vehicle, use this function to reuse the PCM on the
others | | |
| VERIFICATION OF VEHICLE
REPAIR |
After a repair, it is
essential to verify that the fault has been corrected.
| 1. |
Monitor and record the Freeze Frame Data for
the Diagnostic Trouble Code(DTC) which has been
diagnosed. |
| 2. |
Using a Scantool, Clear the
DTCs |
| 3. |
Operate the vehicle within conditions noted in
the freeze frame data or enable
conditions |
| 4. |
Monitor that all rediness test have been
verified as " Complete " |
| 5. |
Are any DTCs present ?

▶ Go to the applicable troubleshoooting
procedure.

▶ System is performing to specification at
this
time. |