In order to control
emissions of the CO, HC and NOx components of the exhaust gas, heated
oxygen sensor (HO2S), mounted on the front side and rear side of catalytic
converter, detects the oxygen content in the exhaust gas. The front HO2S
signal is used to control air/fuel ratio (closed loop fuel control) and
the rear HO2S signal is used to monitor front HO2S and catalyst for proper
operation.The HO2S requires a minimum temperature to operate properly and
provide a closed loop fuel control system. The HO2S contains the heater
element to reduce its warming-up time and ensure its performance during
all driving conditions.
The oxygen sensor
generates a voltage that indicates the difference between the oxygen
content of the exhaust stream and the oxygen content of ambient air. When
the exhaust stream is “rich,” there is more oxygen in the ambient air than
in the exhaust stream, so the voltage will be higher.
This oxygen sensor
varieties use a “bias” voltage to achieve better resolution of the exhaust
stream signal. Some oxygen sensor varieties use a “pumping circuit” to
force ambient air into the sensor to maintain a more pure environment for
comparison.In either case, a cold sensor will tend to indicate voltage
values near the open circuit value. For the “pumping current” sensors,
this open circuit value can be near 3.5 V. Since the Fuel control logic
would incorrectly consider this reading to indicate a very rich mixture
for an extended time, the fuel control logic can not use the oxygen sensor
reading under such conditions.
The PCM controls this
heater element by duty cycle. The main relay supplies voltage to the
heater and the PCM provides a ground circuit for activating the
heater.
Checking output signals
from HO2S under detecting condition, if an output signal within the
detecting condition lasts continuously, PCM sets P2195. MIL(Malfunction
Indicatin Lamp) turns on when the malfunction lasts till consecutive 2
driving cycle.
Item
|
Detecting
Condition
|
Possible cause
|
DTC
Strategy
|
| •
|
Determines if O2 sensor indicates lean
exhaust while in Power Enrichment
(PE) | |
|
EnableConditions
|
| •
|
Sensor not in cooled status
flag |
| •
|
Not in Transient Conditions status
flag |
| •
|
Device control not
active |
| •
|
Min airflow present ≥ 2
g/s |
| •
|
Fuel reduction not
active |
| •
|
Engine running long enough ≥
60sec. |
| •
|
Power Enrichment conditions
present |
| •
|
Engine coolant warm enough ≥ 60°C( 140
°F) |
| •
|
Above conditions met long enough ≥
1.5sec. | |
Threshold
value
|
| •
|
O2 sensor voltage < 0.35V and Air
Fuel Ratio ≤ 13.5 | |
DiagnosisTime
|
| •
|
Contineous
(More than 11.25sec. failure for every
12.5sec. Test) | |
MIL On
Condition
|
|

After warming-up, if
accelerator pedal is released suddenly around 4000rpm, the HO2S signal
reading will be lower than 200mV resulting from Fuel cut-off for the
moment. Conversely, if suddenly accelerator pedal is depressed, HO2S
signal reading will be around 0.6V ~1.0V. At idle, HO2S signal will switch
from lean to rich normally.
A/F Ratio
|
Output
Voltage(V)
|
Rich
|
0.75 ~
1.00V
|
Lean
|
0 ~
0.12V
|

| 1. |
Connect scantool to DLC(Data Link
Connector) |
| 2. |
Warm up the engine to normal operating
temperature. |
| 3. |
Monitor "HO2S(B1S1)" parameter on
scantool
Specification : 0.1 ~
0.9V
|

|
| 4. |
Does the "HO2S(B1S1)" parameter operates
correctly ?

▶Fault is intermittent caused by poor contact
in Sensor’s and/or PCM’s connector or was repairedand PCM memory was
not cleared. Thoroughly check connectors for looseness,
poorconnection, bending, corrosion, contamination, deterioration, or
damage. Repair or replaceas necessary and go to "Verification of
Vehicle Repair" procedure

▶Go to "Component Inspection"
procedure. |
| 1. |
Visual Inspection
| (1) |
Visually check HO2S as
follow.
| A. |
Contamination, deformation or age
of
HO2S(B1/S1) | |
| (2) |
Is the HO2S(B1/S1) normal ?

▶ Go to "Check performance of HO2S" as
follows.

▶ Substitute with a known-good
HO2S(B1S1) and check for proper operation. If the problem is
corrected,replace HO2S(B1S1) and then go to "Verification of
Vehicle Repair"
procedure. | |
| 2. |
Check performance of HO2S
| (1) |
Connect scantool to DLC(Data Link
Connector) |
| (2) |
Warm up the engine to normal operating
temperature. |
| (3) |
Monitor signal waveform of HO2S with
scantool.
Specification : 0.1 ~
0.9V.
|

|
| (4) |
Is the HO2S(B1S1) working properly
?

▶ Substitute with a known-good PCM and
check for proper operation. If the problem is
corrected,replace PCM and then go to "Verification of Vehicle
Repair" procedure.
|
There is a memory reset function
on scantool that can erase optional parts
automaticallydetected and memorized by
PCM. |

▶ Substitute with a known-good
HO2S(B1S1) and check for proper operation. If the problem is
corrected,replace HO2S(B1S1) and then go to "Verification of
Vehicle Repair"
procedure. | |
| VERIFICATION OF VEHICLE
REPAIR |
After a repair, it is
essential to verify that the fault has been corrected.
| 1. |
Monitor and record the Freeze Frame Data for
the Diagnostic Trouble Code(DTC) which has been
diagnosed. |
| 2. |
Using a Scantool, Clear the
DTCs |
| 3. |
Operate the vehicle within conditions noted in
the freeze frame data or enable
conditions |
| 4. |
Monitor that all rediness test have been
verified as " Complete " |
| 5. |
Are any DTCs present ?

▶ Go to the applicable troubleshoooting
procedure.

▶ System is performing to specification at
this
time. |