In order to control
emissions of the CO, HC and NOx components of the exhaust gas, heated
oxygen sensor (HO2S), mounted on the front side and rear side of catalytic
converter, detects the oxygen content in the exhaust gas. The front HO2S
signal is used to control air/fuel ratio (closed loop fuel control) and
the rear HO2S signal is used to monitor front HO2S and catalyst for proper
operation.The HO2S requires a minimum temperature to operate properly and
provide a closed loop fuel control system. The HO2S contains the heater
element to reduce its warming-up time and ensure its performance during
all driving conditions.
The oxygen sensor
generates a voltage that indicates the difference between the oxygen
content of the exhaust stream and the oxygen content of ambient air. When
the exhaust stream is “rich,” there is more oxygen in the ambient air than
in the exhaust stream, so the voltage will be higher.
Some oxygen sensor
varieties use a “bias” voltage to achieve better resolution of the exhaust
stream signal. Some oxygen sensor varieties use a “pumping circuit” to
force ambient air into the sensor to maintain a more pure environment for
comparison. In either case, a cold sensor will tend to indicate voltage
values near the open circuit value. For the “pumping current” sensors,
this open circuit value can be near 3.5 V. Since the Fuel control logic
would incorrectly consider this reading to indicate a very rich mixture
for an extended time, the fuel control logic can not use the oxygen sensor
reading under such conditions.
The PCM controls this
heater element by duty cycle. The main relay supplies voltage to the
heater and the PCM provides a ground circuit for activating the
heater.
Detect when the oxygen
sensor reading has forced closed loop fuel control to stop executing, and
Open Loop fuel control is in effect. This action will happen for OSP (flat
plate) oxygen sensors that are not yet warmed up when the pumping current
is in use. The California Air Resources Board (CARB) will not approve the
current strategy without this modification. CARB considers this Open Loop
operation to be a “default mode of operation,” and thus CARB expects the
Malfunction Indicator Lamp (MIL) to be illuminated.
Checking output signals
from B1S1 every 12 sec. under detecting condition, if an output signal is
near 3.5V for more than 10 sec., PCM sets P2A03. MIL(Malfunction Indicatin
Lamp) turns on when the malfunction lasts till 1 driving
cycle.
Item
|
Detecting
Condition
|
Possible cause
|
DTC
Strategy
|
| •
|
Detects Loss of O2 Ready status, which
would lead to OpenLoop Fueling operation, a default
mode. | |
|
EnableConditions
|
| •
|
DFCO Not present too long ≤
15sec. |
| •
|
No Disabling Faults
Present |
| •
|
All of the above for minimum time ≥
20sec. | |
Threshold
value
|
|
DiagnosisTime
|
| •
|
Contineous
(More than 10 second failure for every
12 second test .) | |
MIL On
Condition
|
|

After warming-up,
Releasing accellerator pedal suddenly around 4000rpm the HO2S signal
reading will be lower than 200mV resulting from Fuel cut-off. Conversely,
sudden depressing accellerator pedal HO2S signal reading will be around
0.6V ~1.0V. At idle, HO2S signal will be switching between lean(below
0.48V) to rich(above 0.48V) normally.
HO2S(B2S1)
|
Warmed
up
|
0 ~
1V
|
Not warmed
up
|
Near
3.5V
|

| 1. |
Connect Scantool &
"ON" |
| 2. |
Warm up the engine to normal operating
temperature. |
| 3. |
Monitor HO2S voltage(B2/S1) parameter on
scantool
Specification : Voltage will vary from
0.1 to 0.9 V
|

|
| 4. |
Is the HO2S parameter displayed within
specifications ?

▶Fault is intermittent caused by poor contact
in the sensor’s and/or PCM’s connector or was repairedand PCM memory
was not cleared. Thoroughly check connectors for looseness, poor
connection,bending, corrosion, contamination, deterioration, or
damage. Repair or replace as necessary and goto "Verification of
Vehicle Repair" procedure.

▶Go to "Component Inspection"
procedure |
| 1. |
Visual Inspection of HO2S
| (1) |
Visually/physically inspect following
items:
| A. |
Inspect the front HO2S for
Contaminated, deteriorated or aged Front
HO2S |
| B. |
If contamination is evident on the
HO2S, replace contaminated
sensor | |
| (2) |
Is the HO2S visually / physically O.K
?

▶ Go to "Check Performance of H02S" as
below

▶ Substitute with a known - good HO2S
and check for proper operation. If the problem is corrected,
replace HO2S and go to "Verification of Vehicle
Repair" | |
| 2. |
Check performance of HO2S
| (1) |
Connect scantool & Engine
"ON" |
| (2) |
Warm-up the engine to normal engine
temperature. |
| (3) |
Monitor signal waveform of HO2S with
scantool
Specification : Voltage will vary
from 0.1 to 0.9 V
|

|
| (4) |
Is the sensor signal switching properly
?

▶ Substitute with a known - good PCM and
check for proper operation. If the problem is corrected,
replace PCM and go to "Verification of Vehicle Repair"
procedure.

▶ Substitute with a known - good HO2S
and check for proper operation. If the problem is corrected,
replace HO2S and go to "Verification of Vehicle Repair"
procedure.
|
There is a memory reset function
on scantool that can erase optional parts
automaticallydetected and memorized by PCM. Before or
after testing PCM on the vehicle, use this function to
reuse the PCM on the
others | | |
| VERIFICATION OF VEHICLE
REPAIR |
After a repair, it is
essential to verify that the fault has been corrected.
| 1. |
Monitor and record the Freeze Frame Data for
the Diagnostic Trouble Code(DTC) which has been
diagnosed. |
| 2. |
Using a Scantool, Clear the
DTCs |
| 3. |
Operate the vehicle within conditions noted in
the freeze frame data or enable
conditions |
| 4. |
Monitor that all rediness test have been
verified as " Complete " |
| 5. |
Are any DTCs present ?

▶ Go to the applicable troubleshoooting
procedure.

▶ System is performing to specification at
this
time. |