The Heated Oxygen
Sensor(HO2S) is used to supply the ECM with information regarding the
composition of the air/fuel mixture. To measure the oxygen content, the
HO2S requires a supply of ambient air as a reference. The HO2S produces a
voltage that varies between 0.1V and 0.9V under normal operating
conditions. The Engine Control Module (ECM) monitors this voltage and
determines if the exhaust gas is lean or rich. If the voltage input at the
ECM is under approx. 0.45V, the exhaust is lean, and if the voltage input
is over approx. 0.45V, the exhaust is rich. The ECM constantly monitors
the HO2S signal during closed loop operation and compensates for a rich or
lean condition by decreasing or increasing injector pluse width as
necessary.
The rear heated oxygen
sensor is mounted on the rear side of the Catalytic (warm-up catalytic
converter) or in the rear exhaust pipe. It detects the catalyst
efficiency. The rear heated oxygen sensor (HO2S) produces a voltage
between 0V and 1V. This rear heated oxygen sensor is used to estimate the
oxygen storage capacity. If a catalyst has good conversion properties, the
oxygen fluctuations are smoothed by the oxygen storage capacity of the
catalyst. If the conversion provided by the catalyst is low due to engine,
poisoning or misfiring, then the oxygen fluctuations sre similar to
signals from the front oxygen sensor.
HARNESS INSPECTION
Refer to DTC P0030,
P0031, P0032, P0036 ~ P0038, P0130, P0131, P0132, P0133, P0134 and P0136 ~
P0140 troubleshooting procedures.
SENSOR INSPECTION
|