The Fuel Level
Sensor(FLS) measures the fuel level in fuel tank and its information is
used to supply the ECM with information regarding the monitoring condition
of the EVAP canister purge system for leak detection. If the fuel level
sensor is monitored for high or low stuck or difference between voltage of
fuel level sensor and voltage deviation of fuel level sensor is exceeds
limited value while driving, this is interpreted by the ECM as a
fault
The ECM monitors the
fuel level in the tank by means of Fuel Level Sensor(FLS). The ECM sets
DTC P0464 if ECM detects that Signal fluctuation is lower than threshold
value.
Item
|
Detecting
Condition
|
Possible Cause
|
DTC Strategy
|
|
| •
|
Poor connection or damaged
harness |
|
Enable Conditions
|
| •
|
Vehicle speed >35km/h(22mph) for 20
sec. |
| •
|
Wheel speed gradient < 1.8/1000 for
20 sec. |
| •
|
11V< Battery voltage
<16V | |
Threshold Value
|
| •
|
Difference between measured fuel level
signal and filtered fuel level signal >
50% | |
Diagnostic Time
|
|
MIL On Condition
|
|
Fuel Level
|
Gauge
|
Resistance(Ω)
|
E(Empty)
|
Approx.
182~186
|
1/2
|
Approx.
65~67
|
F(Full)
|
Approx.
14~16
|

|
If any codes relating to Fuel Level
Sensor(FLS) are present, do ALL REPAIRS associated with those codes
before proceeding with this troubleshooting
tree. |
| 1. |
Start engine to normal operating
temperature
|
Evaporative Emissions Systems (EVAP)
Leak Tests can be run by the Scan Tool. The tests are
automated and provide either a pass-fail result or directions
to check for
DTCs. | |
| 2. |
Install scan tool and clear
DTC |
| 3. |
Perform "05 EVAP. LEAKAGE TEST" mode referring
to enable conditions as below
|
EVAP. Leakage Test enable
conditions
- Following conditions must be fulfilled
to start the test.
1) Engine warm up at Idle
Status
2) No relevant DTC
3) Fuel level is below
80% |

|
| 4. |
Is DTC P0464 set again?

▶ Go to next step as below

▶ Fault is intermittent caused by poor contact
in the sensor's and/or ECM's connector or was repaired and ECM
memory was not cleared. Thoroughly check connectors for looseness,
poor connection, bending, corrosion, contamination, deterioration,
or damage. Repair or replace as necessary and go to "Verification
vehicle Repair" procedureition |
| SIGNAL CIRCUIT
INSPECTION |
| 2. |
Disconnect FLS
connector |
| 3. |
Ignition "ON" & Engine
"OFF" |
| 4. |
Measure voltage between terminal 1 of the FLS
harness connector and chassis ground
Specification : Approx. 11
V
|

|
| 5. |
Is voltage within the
specification?

▶ Go to next step as below.

▶ Repair as necessary and go to "Verification
of Vehicle Repair" procedure |
| GROUND CIRCUIT
INSPECTION |
| 2. |
Measure resistance between terminal 3 of the
FLS harness connector and chassis ground
Specification : Approx.
0Ω
|

|
| 3. |
Is resistance within the
specification?

▶ Go to next step as below.

▶ Repair as necessary and go to "Verification
of Vehicle Repair" procedure |
| TERMINAL AND CONNECTOR
INSPECTION |
| 1. |
Many malfunctions in the electrical system are
caused by poor harness(es) and terminals. Faults can also be caused
by interference from other electrical systems, and mechanical or
chemical damage. |
| 2. |
Thoroughly check connectors for looseness,
poor connection, bending, corrosion, contamination, deterioration,
or damage. |
| 3. |
Has a problem been found?

▶ Repair as necessary and go to "Verification
of Vehicle Repair" procedure

▶ Go to next step as
below |
| 2. |
Disconnect FLS harness
connector |
| 3. |
Measure resistance between terminals 1 and 3
of the FLS connector(Component side).
Specification :
Fuel Level
|
Gauge
|
Resistance(Ω)
|
E(Empty)
|
Approx. 182~186
|
1/2
|
Approx. 65~67
|
F(Full)
|
Approx. 14~16
|

|
| 4. |
Is resistance within the
specification?

▶ Check for poor connection between ECM and
component: backed out terminal, improper mating, broken locks or
poor terminal to wire connection. Repair as necessary and go to
"Verification of Vehicle Repair" procedure

▶ Check FLS for contamination, deterioration,
or damage. Substitute with a known-good FLS and check for proper
operation. If the problem is corrected, replace FLS and then go to
"Verification of Vehicle Repair"
procedure |
| VERIFICATION OF VEHICLE
REPAIR |
| 1. |
Reconnect all EVAP hardware that was
previously disconnected |
| 2. |
Start engine to normal operating
temperature
|
Evaporative Emissions Systems (EVAP)
Leak Tests can be run by the Scan Tool. The tests are
automated and provide either a pass-fail result or directions
to check for
DTCs. | |
| 3. |
Install scan tool and clear
DTC |
| 4. |
Perform "EVAP. LEAKAGE TEST" mode referring to
enable conditions as below
|
EVAP. Leakage Test enable
conditions
- Following conditions must be fulfilled
to start the test.
1) Engine warm up at Idle
Status
2) No relevant DTC
3) Fuel level is below
80% | |
| 5. |
Monitoring for (pending) DTC.Is the same DTC
set?

▶ Go to the applicable troubleshooting
procedure.

▶ System performing to specification at this
time. |