The ABS ECU supplies
battery power to all solenoid valves by way of a valve relay which is
controlled by the Electronic Control UNIT(ECU). The valve relay and all
solenoid valves are installed inside the HECU ( Hydraulic and Electronic
Control Unit ).
ABS ECU monitors voltage
of the valve relay to check if ABS ECU can perform ABS control normally.
When the valve relay is switched to ON, the HECU will set this code if the
solenoid drive voltage is below permissible voltage ranges for a period of
time. When the valve relay is switched to OFF, the HECU sets this code if
the solenoid drive voltage is over the permissible voltage range for a
period of time.
Item
|
Detecting
Condition
|
Possible
cause
|
DTC
Strategy
|
Battery
Voltage Monitoring
|
| •
|
Open or short of power supply
circuit |
| •
|
Faulty of the valve relay fuse(20
A) | |
Enable
Conditions
|
| 1. |
Watchdog and VR(valve relay) function is
tested during startup.FSA test(Fail Save Circuit test) detects
if the VR/Enable remains in off position when it is turned on
and vice versa. Reason could be short to GND or UZ(ECU voltage
supply), interrupted lines or a defective output stage
etc. |
| 2. |
A Fault is detected if UVR(valve relay
voltage) < 0.8 * UZ for a time t > 500
ms. |
| 3. |
This test evaluates the function of the
VR (valve relay) periodically. The VR is switched off and back
on. VR malfunction and UVR short to UZ or UBVR(supply solenoid
valves) and medium or high ohmic short of UVR (or a valve) to
UZ, UBVR(supply solenoid valves) or GND are
detected. | |
Monitoring
period
|
1.Once during
startup. 2,3.Continuous
|
Effect
|
No valve
actuation possible.
|
| TERMINAL & CONNECTOR
INSPECTION |
| 1. |
Many malfunctions in the electrical system are
caused by poor harness(es) and terminals. Faults can also be caused
by interference from other electrical systems, and mechanical or
chemical damage. |
| 2. |
Thoroughly check connectors for looseness,
poor connection, bending, corrosion, contamination, deterioration,
or damage. |
| 3. |
Has a problem been found?

▶ Repair as necessary and then go to
"Verification of Vehicle Repair" procedure.

▶ Go to the next
step. |
| POWER SUPPLY CIRCUIT
INSPECTION |
| 2. |
Disconnect HECU
connector. |
| 3. |
Ignition "ON" & Engine
"OFF". |
| 4. |
Measure voltage between terminal "3" of the
HECU harness connector and chassis ground.
Specification :Approx.
B+
|

Is the measured voltage within
specifications?

▶ Go to "Ground Circuit Inspection"
procedure.

▶ Check for open or short in power harness
between battery terminal(+) and terminal "3" of the HECU harness
connector. Check for open or blown 20A fuse . Repair as necessary
and then go to "Verification of vehicle Repair"
procedure. |
| GROUND CIRCUIT
INSPECTION |
| 2. |
Disconnect HECU
connector. |
| 3. |
Measure resistance between terminal "4" of the
HECU harness connector and chassis ground.
Specification :Approx.below 1
Ω
|
Is the measured resistance within
specifications?

▶ Go to "Component Inspection"
procedure.

▶ Check for damaged harness and poor
connection between terminal "4" of the HECU harness connector and
chassis ground. Repair as necessary and then go to "Verification of
vehicle Repair" procedure. |
| 2. |
Engine "ON".
Does warning lamp remain On?

▶ Substitute with a known-good HECU and check
for proper operation. If problem is corrected, replace HECU and then
go to "Verification of Vehicle Repair" procedure.

▶ Fault is intermittent caused by open or
short of power harness and/or faulty HECU or was repaired and HECU
memory was not cleared. Go to the applicable troubleshooting
procedure. |
| VERIFICATION OF VEHICLE
REPAIR |
After a repair, it is
essential to verify that the fault has been corrected.
| 1. |
Connect scantool and select "Diagnostic
Trouble Codes(DTCs)" mode. |
| 2. |
Using a scantool, Clear
DTC. |
| 3. |
Operate the vehicle within DTC Detecting
Condition in General Information.
Are any DTCs present?

▶ Go to the applicable troubleshooting
procedure.

▶ System performing to specification at this
time. |