Home › Heating,Ventilation, Air Conditioning › Air conditioning System › Photo sensor

Air conditioning System › Photo sensor: Repair procedures

INSPECTION
1.
Ignition "ON".
2.
Using the scan tool.
3.
Emit intensive light toward photo sensor using sunshine, and check the output absolute voltage change.
4.
The absolute voltage will rise with higher intensive light and reduce with lower intensive light.
When checking photo sensor, select a place where is exposed to sunshine directly.

REPLACEMENT
1.
Disconnect the negative (-) battery terminal.
2.
Using the (-) driver, Remove the photo sensor (B) from the right part of defrost nozzle (A).
3.
Disconnect the connector.

4.
Installation is the reverse order of removal.