Home
›
Heating,Ventilation, Air Conditioning
›
Air conditioning System
›
Air Quality Sensor(AQS)
Air conditioning System › Air Quality Sensor(AQS): Repair procedures
INSPECTION
1.
Ignition "ON".
2.
Using the scan tool.
3.
Check the output voltage of AQS between terminals 4 and 5.
Specification
Condition
Output signal
Intake
Normal condition
4 ~ 5V
Fresh
Hazardous gas detection
0 ~ 1V
Recirculation
REPLACEMENT
1.
Disconnect the negative (-) battery terminal.
2.
Remove the front bumper (Refer to the BD group).
3.
Remove the AQS sensor (A) after loosening the mounting screws.
4.
Install in the reverse order of removal.