Home › Heating,Ventilation, Air Conditioning › Air conditioning System › Humidity Sensor

Air conditioning System › Humidity Sensor: Repair procedures

INSPECTION
1.
Ignition "ON".
2.
Using the scan tool.
3.
Check the frequency of humidity sensor between terminals 2 and 3.
Humidity (%)
Frequency between terminals 2 and 3(Hz)
0
7351± 10%
10
7224± 10%
20
7100± 5%
30
6976 ± 5%
50
6728 ± 5%
60
6600 ± 5%
70
6468 ± 5%
80
6330 ± 5%
90
6186 ± 10%
100
6033 ± 10%

4.
If the measured resistance is not specification, substitute with a known-good humidity sensor and check for proper operation.
5.
If the problem is corrected, replace the Humidity sensor.
REPLACEMENT
1.
Disconnect the negative (-) battery terminal.
2.
Remove the lower crash panel (A) (Refer to BD group).
3.
Disconnect humidity sensor connector.
4.
Loosen the mounting screws (B) and then remove the humidity sensor (C).

5.
Installation is the reverse order of removal.