Home › Heating,Ventilation, Air Conditioning › Blower › Control Panel

Blower › Control Panel: Repair procedures

REPLACEMENT
1.
Disconnect the negative (-) battery terminal.
2.
Remove the center facia panel (A) after pulling it by using a regular screwdriver (-).

3.
Disconnect the connectors (B) from the center facia.

4.
Remove the heater & A/C controller (C).

5.
Install in the reverse order of removal.