Controller › Manual Controller: Repair procedures

SELF-DIAGNOSIS
Self-diagnosis process
The F.A.T.C. module self test feature will detect electrical malfunction and provide error codes for system components with suspected failures.

Turn off the A/C system during the DTC check.
HOW TO READ SELF-DIAGNOSTIC CODE
1.
After the display panel flickers three times every 0.5 second, the corresponding fault code flickers on the setup temperature display panel every 0.5 second and will show two figures.
2.
Fault code
Fault code
Fail description
Control unit
Scan tool
(DTC)
00
-
Normal
11
B1234
In-car temperature sensor open (High)
12
B1233
In-car temperature sensor short (Low)
13
B1238
Ambient temperature sensor open (High)
14
B1237
Ambient temperature sensor short (Low)
15
B1202
Water temperature sensor open (High)
16
B1203
Water temperature sensor short (Low)
17
B1242
Evaporator temperature sensor open (High)
18
B1241
Evaporator temperature sensor short (Low)
19
B1245
Air mix potentiometer open (Low) - Driver
19
B1246
Air mix potentiometer short (High) - Driver
20
B2406
Air mix motor failure (Driver)
21
B1249
Direction potentiometer open (Low) - Driver
21
B1250
Direction potentiometer short (High) - Driver
22
B2409
Direction control motor failure (Driver)
23
B1200
Humidity sensor open (High)
24
B1201
Humidity sensor short (Low)
25
B1208
Intake potentiometer open (Low)
25
B1209
Intake potentiometer short (High)
26
B2408
Intake motor failure
27
B1257
AQS sensor open (High)
28
B1258
AQS sensor short (Low)
29
B1259
AQS sensor failure

3.
Fault code display
(1)
Continuance operation

(2)
Step operation

4.
If a fault code is displayed during the DTC check, Inspect a malfunction cause by referring to the DTC code.
5.
Fail safe
(1)
In-car temperature sensor: Control with the value of 25°C(77°F)
(2)
Ambient temperature sensor: Control with the value of 20°C(67°F)
(3)
Evaporator temperature sensor: Control with the value of -2°C(28.4°F)
(4)
Humidity sensor: Control with the value of 10%
(5)
Temperature sensor : Control with the value of -2°C (28.4°F)
(6)
Temperature control actuator (Air mix potentiometer):
If temperature setting 17°C-24.5°C, fix at maximum cooling position.
If temperature setting 25°C-32°C, fix at maximum heating position.
(7)
Mode control actuator (Direction potentiometer):
Fix vent position, while selecting vent mode.
Fix defrost position, while selecting all except vent mode.
(8)
Intake control actuator :
Fix fresh position, while selecting fresh mode.
Fix recirculation position, while selecting recirculation mode.
(9)
AQS sensor : AQS operation OFF.
A.
Intake position : The position before selecting AQS switch.
REPLACEMENT
1.
Disconnect the negative (-) battery terminal.
2.
Remove the center facia panel (A) after pulling it by using a regular screw driver (-).

3.
Disconnect the connectors (B) from the center facia.

4.
Remove the heater & A/C controller (C).

5.
Install in the reverse order of removal.