Automatic Transaxle Control System › Shift Lever: Repair procedures
INSPECTION
1.
Adjusting method for T/M control
cable
(1)
Set room side lever and T/M side lever
to "N" position.
(2)
Connect room side lever and shift
cable.
(3)
Connect T/M side lever(A) to cable in a
following orders.
A.
Push cable(B) lightly to "F"
direction shown to eliminate FREE PLAY of
cable.
B.
Tighten adjusting
nut.
(4)
After adjusting according to (2)-(4).
Check to be sure that this part operates surely at each range
of T/M side corresponding to each position of room
lever.
REMOVAL
1.
Remove the center console cover(A) after
dissconnecting the connectors (3EA).