The TCM(PCM) controls
the locking and unlocking of the Torque Converter Clutch ( or Damper
Clutch ), to the input shaft of the transmission, by appling hydraulic
pressure. The main purpose of T/C clutch control is to save fuel by
decreasing the hydraulic load inside the T/C. The TCM(PCM) outputs duty
pulses to control the Damper Clutch Control Solenoid Valve(DCCSV) and
hydraulic pressure is applied to the DC according to the DCC duty ratio
value. When the duty ratio is high, high pressure is applied and the
Damper Clutch is locked. The normal operating range of the Damper Clutch
Control duty ratio value is from 30%(unlocked) to
85%(locked).
The TCM(PCM) checks the
Damper Clutch Control Signal by monitoring the feedback signal from the
solenoid valve drive circuit. If an unexpected signal is monitored (for
example, high voltage is detected when low voltage is expected, or low
voltage is detected when high voltage is expected) the TCM(PCM) judges
that DCCSV circuit is malfunctioning and sets this code.
Item
|
Detecting Condition & Fail
Safe
|
Possible cause
|
DTC Strategy
|
|
※
TORQUE CONVERTER(DAMPER) CLUTCH : TCC
| •
|
Open or short in
circuit |
| •
|
Faulty TCC SOLENOID
VALVE |
|
Enable Conditions
|
| •
|
16V > Voltage Battery
>10V |
| •
|
In gear state(no gear shifting) 500msec
is passed from turn on the
relay | |
Threshold value
|
| •
|
Feedback voltage from DCC control
solenoide > Vb-2V and DCC control duty is
100% |
| •
|
Feedback voltage from DCC control
solenoide ≤ 5.5V and DCC control duty is
0% | |
Diagnostic Time
|
|
Fail Safe
|
| •
|
Locked in 3rd gear.(Control relay
off) | |
Solenoid Valve for
Pressure Control
| • |
Sensor type : Normal open
3-way |
| • |
Operating temperature :
-30°C~130°C(-22~266°F) |
| -
|
LR, 2ND, UD, OD, RED : 61.27Hz (at the
ATF temp. -20°C above) |
|
| -
|
2.7~3.4Ω(68°F or 20°C) - LR, 2ND, UD,
OD, RED, DCC |
| -
|
4.3~4.4Ω(68°F or 20°C) -
VFS | |
| • |
Surge voltage : 56 V(except
VFS) |

| 1. |
Connect scantool to data link
connector(DLC) |
| 3. |
Monitor the "TCC SOL. VALVE" parameter on the
scantool |
| 4. |
Select "D RANGE" and Operate "TCC SOLENOID
DUTY" more than 85% |

| 1. |
Does "TCC SOLENOID DUTY " follow the reference
data?

▶ Fault is intermittent caused by poor contact
in the sensor's and/or TCM(PCM)'s connector or was repaired and
TCM(PCM) memory was not cleared. Thoroughly check connectors for
looseness, poor connection, bending, corrosion, contamination,
deterioration or damage.Repair or replace as necessary and go to
"Verification of Vehicle Repair" procedure.

▶ Go to "Terminal&Connector Inspection "
procedure. |
| TERMINAL & CONNECTOR
INSPECTION |
| 1. |
Many malfunctions in the electrical system are
caused by poor harness and terminals. Faults can also be caused by
interference from other electrical systems, and mechanical or
chemical damage. |
| 2. |
Thoroughly check connectors for looseness,
poor connection, bending, corrosion, contamination, deterioration,
or damage. |
| 3. |
Has a problem been found?

▶ Repair as necessary and then go to
"Verification of Vehicle Repair" procedure.

▶ Go to "Power Supply Circuit Inspection"
procedure. |
| POWER SUPPLY CIRCUIT
INSPECTION |
| 1. |
Disconnect "A/T SOLENOID VALVE"
connector. |
| 2. |
Measure voltage between teminal "6" of the
sensor harness connector and chassis
ground. |
| 3. |
Turn ignition switch OFF → ON
Specification: 12V is measured only for
approx. 0.5sec
|

|
| 4. |
Is voltage within specifications?

▶ Go to "Signal circuit inspection"
procedure.

▶ Check that A/T-30A Fuse in engine room
junction is installed or not blown.
▶ Check for open in harness. Repair as
necessary and Go to "Verification of Vehicle Repair"
procedure. |
| SIGNAL CIRCUIT
INSPECTION |
| 1. |
Check signal circuit open
inspection.
| (2) |
Disconnect "A/T SOLENOID VALVE"
connector and "TCM(PCM)"
connector. |
| (3) |
Measure resistance between terminal "9"
of the ATM SOLENOID VALVE harness connector and terminal "18"
of the TCM(PCM) harness connector.
Specification: approx. 0
Ω
|

|
| (4) |
Is resistance within
specifications?

▶ Go to "Check signal circuit short
Inspection" procedure.

▶ Check for open in harness. Repair as
necessary and Go to "Verification of Vehicle Repair"
procedure. | |
| 2. |
Check signal circuit short
inspection
| (2) |
Disconnect "A/T SOLENOID VALVE"
connector and "TCM(PCM)"
connector |
| (3) |
Measure resistance between terminal "9"
of the ATM SOLENOID VALVE harness and chassis
ground.

|
| (4) |
Is resistance within
specifications?

▶ Go to "Component Inspection"
procedure.

▶ Check for short to ground in harness.
Repair as necessary and Go to "Verification of Vehicle Repair"
procedure. | |
| 1. |
CHECK SOLENOID VALVE
| (2) |
Disconnect "A/T SOLENOID VALVE"
connector. |
| (3) |
Measure resistance between terminal "9"
and terminal "6" of the ATM SOLENOID VALVE harness
connector.
Specification: Approximately
2.7~3.4 Ω [20°C(68°F)]
|

|
| (4) |
Is resistance within
specification?

▶ Go to "CHECK TCM(PCM)" as
below.

▶ Replace TCC SOLENOID VALVE as
necessary and go to "Verification of Vehicle Repair"
procedure. | |
| 2. |
CHECK TCM(PCM)
| (1) |
Connect scantool to data link
connector(DLC). |
| (2) |
Ignition "ON" & Engine
"OFF". |
| (3) |
Select A/T Solenoid valve Actuator test
and Operate Actuator test. |
| (4) |
Can you hear operating sound for TCC
SOLENOID VALVE Actuator Testing Function?

▶ Go to "Verification of Vehicle Repair"
procedure.

▶ Replace TCM(PCM) as necessary and go
to "Verification of Vehicle Repair" procedure
ACTUATOR TEST
CONDITION
| B. |
TRANSAXLE RANGE SWITCH is
normal |
| E. |
Throttle position sensor<
1V |
| |
| VERIFICATION OF VEHICLE
REPAIR |
After a repair, it is
essential to verify that the fault has been corrected.
| 1. |
Connect scan tool and select "Diagnostic
Trouble Codes(DTCs)" mode. |
| 2. |
Using a scantool, Clear
DTC. |
| 3. |
Operate the vehicle within DTC Enable
conditions in General information. |
| 4. |
Are any DTCs present?

▶ Go to the applicable troubleshooting
procedure.

▶ System performing to specification at this
time. |