INSPECTION
HAZARD LAMP SWITCH
1.
Disconnect the negative (-) battery terminal.
2.
Remove the crash pad garnish (A) after pulling it by using regular screw driver (-). Take care of fixing clips(C).
3.
Remove the center facia panel (B) after loosening the screws.
4.
Disconnect the connectors(A).
5.
Remove the hazard lamp switch from the center facia panel.
6.
Operate the switch and check for continuity between terminals with an ohmmeter.