
The ABS ECU supplies
battery power to all solenoid valves by way of a valve relay which is
controlled by the Electronic Control UNIT(ECU). The valve relay and all
solenoid valves are installed inside the HECU ( Hydraulic and Electronic
Control Unit ).
ABS ECU monitors
voltage of the valve relay to check if ABS ECU can perform ABS control
normally. When the valve relay is switched to ON, the HECU will set this
code if the solenoid drive voltage is below permissible voltage ranges for
a period of time. When the valve relay is switched to OFF, the HECU sets
this code if the solenoid drive voltage is over the permissible voltage
range for a period of time.
Item
|
Detecting Condition
|
Possible cause
|
DTC Strategy
|
Battery Voltage Monitoring
|
| •
|
Open or short of power supply
circuit |
| •
|
Faulty of the valve relay fuse(20
A) | |
Enable Conditions
|
| 1. |
Watchdog and VR(valve relay) function
is tested during startup.FSA test(Fail Save Circuit test)
detects if the VR/Enable remains in off position when it is
turned on and vice versa. Reason could be short to GND or
UZ(ECU voltage supply), interrupted lines or a defective
output stage etc. |
| 2. |
A Fault is detected if UVR(valve relay
voltage) < 0.8 * UZ for a time t > 500
ms. |
| 3. |
This test evaluates the function of
the VR (valve relay) periodically. The VR is switched off and
back on. VR malfunction and UVR short to UZ or UBVR(supply
solenoid valves) and medium or high ohmic short of UVR (or a
valve) to UZ, UBVR(supply solenoid valves) or GND are
detected. | |
Monitoring period
|
1.Once during startup. 2,3.Continuous
|
Effect
|
No valve actuation
possible.
|
| TERMINAL & CONNECTOR
INSPECTION |
| 1. |
Many malfunctions in the electrical system
are caused by poor harness(es) and terminals. Faults can also be
caused by interference from other electrical systems, and mechanical
or chemical damage. |
| 2. |
Thoroughly check connectors for looseness,
poor connection, bending, corrosion, contamination, deterioration,
or damage. |
| 3. |
Has a problem been found?

▶ Repair as necessary and then go to
"Verification of Vehicle Repair" procedure.

▶ Go to the next
step. |
| POWER SUPPLY CIRCUIT
INSPECTION |
| 2. |
Disconnect HECU
connector. |
| 3. |
Ignition "ON" & Engine
"OFF". |
| 4. |
Measure voltage between terminal "3" of the
HECU harness connector and chassis ground.
Specification :Approx.
B+
|

Is the measured voltage within
specifications?

▶ Go to "Ground Circuit Inspection"
procedure.

▶ Check for open or short in power harness
between battery terminal(+) and terminal "3" of the HECU harness
connector. Check for open or blown 20A fuse . Repair as necessary
and then go to "Verification of vehicle Repair"
procedure. |
| GROUND CIRCUIT
INSPECTION |
| 2. |
Disconnect HECU
connector. |
| 3. |
Measure resistance between terminal "4" of
the HECU harness connector and chassis ground.
Specification :Approx.below 1
Ω
|
Is the measured resistance within
specifications?

▶ Go to "Component Inspection"
procedure.

▶ Check for damaged harness and poor
connection between terminal "4" of the HECU harness connector and
chassis ground. Repair as necessary and then go to "Verification of
vehicle Repair" procedure. |
| 2. |
Engine "ON".
Does warning lamp remain On?

▶ Substitute with a known-good HECU and
check for proper operation. If problem is corrected, replace HECU
and then go to "Verification of Vehicle Repair"
procedure.

▶ Fault is intermittent caused by open or
short of power harness and/or faulty HECU or was repaired and HECU
memory was not cleared. Go to the applicable troubleshooting
procedure. |
| VERIFICATION OF VEHICLE
REPAIR |
After a repair, it is
essential to verify that the fault has been corrected.
| 1. |
Connect scantool and select "Diagnostic
Trouble Codes(DTCs)" mode. |
| 2. |
Using a scantool, Clear
DTC. |
| 3. |
Operate the vehicle within DTC Detecting
Condition in General Information.
Are any DTCs present?

▶ Go to the applicable troubleshooting
procedure.

▶ System performing to specification at this
time. |