Air conditioning System › Ambient sensor: Repair procedures
INSPECTION
1.
Ignition
"OFF".
2.
Disconnect ambient temperature sensor
connector.
3.
Check the resistance of ambient temperature
sensor between terminals 1 and 2 whether it is changed by changing
temperature of the ambient temperature sensor.
Specification
Ambient temperature
[°C(°F)]
Resistance between
terminals 1 and 2 (KΩ±3%)
-20 (-4) 0
(32) 25 (77) 50 (122) 80
(176)
271.1 95.1 30.0 10.9 3.83
4.
If the measured resistance is not
specification, substitute with a known-good ambient temperature
sensor and check for proper
operation.
5.
If the problem is corrected, replace the
ambient temperature sensor.
REPLACEMENT
1.
Disconnect the negative (-) battery
terminal.
2.
Remove the front bumper. (Refer to BD
group)
3.
Remove the ambient temperature sensor(A)
after loosening the mounting bolt.