Remove the power mosfet.Measure resistance
between Drain and Source using resistance tester. You can estimate
whether power mosfet is failure or not refering to the
specification.
FET Fail Check
Resistance
(Drain-Source)
Specification
Measuring method
1
2
Mosfet
Drain
+
-
Source
-
+
Classification
Normal
∞
About 3 MΩ
Short
About 0~300Ω
About 0~300Ω
Open
∞
∞
3.
If If the measured resistance is not normal
specification, replace the power
mosfet.
4.
If it is normal, install the power mosfet
and ignition "ON".
Manually operate the control switch and
measure the voltage between pin 1 and 2 of blower
motor.
5.
Select the control switch to raise voltage
until high speed.
Fan
Motor voltage(V) ±
0.5V
First speed
3.8
Second speed
4.9
Third speed
6.1
Fourth speed
7.2
Fifth speed
8.3
Sixth speed
9.5
Seventh speed
10.6
Eighth speed
Battery
(+)
6.
If the measured voltage is not within
specification, substitute with a known-good power mosfet and check
for proper operation.
7.
If the problem is corrected, replace the
power mosfet.
REPLACEMENT
1.
Disconnect the negative (-) battery
terminal.
2.
Disconnect the connector of the power mosfet
at the below blower unit.
3.
Remove the power mosfet (A) after loosening
the mounting screws.