The automatic
TRANSAXLE fluid(ATF) temperature sensor is installed in the Valve Body.
This sensor uses a thermistor whose resistance changes according to the
temperature changes. The TCM supplies a 5V reference voltage to the
sensor, and the output voltage of the sensor changes when the ATF
temperature varies. The automatic TRANSAXLE fluid(ATF) temperature
provides very important data for the TCM's control of the Torque Converter
Clutch, and is also used for many other purposes.
This DTC code is set
when the ATF temperature output voltage is lower than a value generated by
thermistor resistance, in a normal operating range, for approximately 1
second or longer. The TCM regards the ATF temperature as fixed at a value
of 80 °C.
Item
|
Detecting
Condition
|
Possible
Cause
|
DTC
Strategy
|
|
| •
|
Sensor signal circuit is short to
ground. |
|
Enable
Conditions1)
|
| •
|
Engine speed >1000rpm and Output
speed >1000rpm |
| •
|
Accumulated time in above two
condition 5min |
| •
|
Voltage of Battery
>10V |
| •
|
A/T oil temp. at start-up and ambient
temp.
(<50°C) and (>-7°C) or A/T oil
temp. at start-up <30°C |
| •
|
Engine coolant temp. increase since
start-up >40°C
In condition that A/T oil temp.
changing <2°C | |
Enable
Conditions2)
|
| •
|
A/T oil temp. at previous engine-off
>50°C |
| •
|
Engine coolant temp. at previous
engine-off >73.5°C |
| •
|
Engine coolant temp. drop from the
previous engine-off >34°C |
| •
|
Intake air temperature <
35°C |
| •
|
Voltage of Battery
>10V |
| •
|
Time after TCM turns on
0.5sec
In condition that A/T oil temp. drop
<2°C from the previous
engine-off | |
Enable
Conditions3)
|
No ≥ 1000rpm, Ne ≥
1000rpm for 5min cumulative and the engine coolant
temperature≥73.5°C In condition that
OTS output ≤ -23°C
|
Threshold
Value
|
|
Diagnostic
Time
|
|
Fail Safe
|
| •
|
Learning control and Intelligent shift
are inhibited. |
| •
|
Fluid temperature is regarded as
80°C | |
TEMP.[°C(°F)]
|
RESISTANCE(kΩ)
|
TEMP.[°C(°F)]
|
RESISTANCE(kΩ)
|
40(40)
|
139.5
|
80(176)
|
1.08
|
20(4)
|
47.7
|
100(212)
|
0.63
|
0(32)
|
18.6
|
120(248)
|
0.38
|
20(68)
|
8.1
|
140(284)
|
0.25
|
40(104)
|
3.8
|
160(320)
|
0.16
|
60(140)
|
1.98
|
|
| 1. |
Connect scantool to data link
connector(DLC) |
| 3. |
Monitor the "TRANSAXLE FLUID TEMPERATURE
SENSOR" parameter on the scantool
Specification :
Increasing Gradually
|


Fig 1) Normal
Fig 2) Signal harness Open
Fig 3) Signal harness
Sho |
| 4. |
Does "TRANSAXLE FLUID TEMPERATURE SENSOR "
follow the referance data?
|

|
▶ Fault is
intermittent caused by poor contact in the sensor's and/or
TCM(PCM)'s connector or was repaired and TCM(PCM) memory was
not cleared. Throughly check connectors for looseness, poor
connection, bending, corrosion, contamination, deterioration
or damage.Repair or replace as necessary and go to
"Verification Of Vehicle Repair" procedure.
|
|

|
▶ Go to "W/Harness
Inspection"
procedure.
|
|
| Terminal and Connector
Inspection |
| 1. |
Many malfunctions in the electrical system
are caused by poor harness and terminals. Faults can also be caused
by interference from other electrical systems, and mechanical or
chemical damage. |
| 2. |
Thoroughly check connectors for looseness,
poor connection, bending, corrosion, contamination, deterioration,
or damage. |
| 3. |
Has a problem been found?
|

|
▶ Repair as
necessary and go to "Verification vehicle Repair"
procedure
|
|

|
▶ Go to "Component
Inspection"
procedure
|
|
| ■ Check
"TRANSAXLE FLUID TEMPERATURE SENSOR" |
| 2. |
Disconnect the "TRANSAXLE FLUID TEMPERATURE
SENSOR" connector |
| 3. |
Measure the resistance between terminals "1"
and "2" of the "TRANSMISSION FLUID TEMPERATURE SENSOR".
Specification :
Refer to " Reference data"
|

[Reference data]
TEMP.[°C(°F)]
|
RESISTANCE(kΩ)
|
TEMP.[°C(°F)]
|
RESISTANCE(kΩ)
|
40(40)
|
139.5
|
80(176)
|
1.08
|
20(4)
|
47.7
|
100(212)
|
0.63
|
0(32)
|
18.6
|
120(248)
|
0.38
|
20(68)
|
8.1
|
140(284)
|
0.25
|
40(104)
|
3.8
|
160(320)
|
0.16
|
60(140)
|
1.98
|
|
|
| 4. |
Is resistance within
specifications?
|

|
▶ Go to "CHECK
PCM/TCM " as below
|
|

|
▶ Replace
"TRANSAXLE FLUID TEMPERATURE SENSOR" as necessary and Go to
"Verification Of Vehicle Repair" procedure.
|
|
| 1. |
Ignition "ON" & Engine
"OFF". |
| 2. |
Connect "TRANSAXLE FLUID TEMPERATURE SENSOR"
connector. |
| 3. |
Install scantool and slect a
SIMU-SCAN, |
| 4. |
Simulate voltage (0→5V) to "TRANSMISSION
FLUID TEMPERATURE SENSOR" signal circuit.

Fig 1) INPUT 1.00V → 70°C
Fig 2) INPUT 2.00V → 40°C
※ The values are subject to change according
to vehicle model or conditions. |
| 5. |
Is FLUID TEMP. SENSOR signal value changed
according to simulation voltage?
|

|
▶ Thoroughly check
connectors for looseness, poor connection, bending, corrosion,
contamination, deterioration, or damage. Repair or replace as
necessary and then go to "Verification of Vehicle Repair"
procedure.
|
|

|
▶ Substitute with a
known-good PCM/TCM and check for proper operation. If the
problem is corrected, replace PCM/TCM as necessary and then
go to "Verification of Vehicle Repair" procedure.
|
|
| Verification Of Vehicle
Repair |
After a repair, it is
essential to verify that the fault has been corrected.
| 1. |
Connect scan tool and select "Diagnostic
Trouble Codes(DTCs)" mode. |
| 2. |
Using a scantool, Clear
DTC. |
| 3. |
Operate the vehicle within DTC Enable
conditions in General information. |
| 4. |
Are any DTCs present ?
|

|
▶ Go to the
applicable troubleshooting procedure.
|
|

|
▶ System performing
to specification at this
time.
|
|