The Evaporator
Temperature Sensor located on heater unit, detects the core temperature
and interrupts compressor relay power, in order to prevent evaporator
freezing by excessive cooling. It is a negative type thermistor whose
resistance is inversely proportional to temperature.
The Heater & A/C
controller sets DTC B1242 if there is an open circuit in Evaporator Temp.
Sensor signal harness or the measured resistance value of sensor is more
than threshold value(about 13.6kΩ)
Item
|
Detecting
Condition
|
Possible
cause
|
DTC Strategy
|
|
| •
|
Open Circuit in
harness |
| •
|
Faulty Evaporator Temp.
Sensor |
| •
|
Faulty Heater & A/C
controller | |
Threshold value
|
|
Detecting time
|
|
Fail safe
|
| •
|
Control with the value of
-2°C(28.4°F) | |
Temperature[°C(°F)]
|
Resistance(kΩ)
|
Temperature[°C(°F)]
|
Resistance(kΩ)
|
-10(14)
|
13.6
|
15(59)
|
3.9
|
0(32)
|
8
|
30(86)
|
2
|
5(41)
|
6.2
|
40(104)
|
1.3
|
10(50)
|
4.9
|
50(122)
|
0.9
|
| 1. |
Connect scantool to Data Link
Connector(DLC). |
| 3. |
Monitor the "Evaporative Sensor" parameter
on the Scantool.

|
| 4. |
Is the DTC B1242 present and is parameter of
"Evaporative Sensor" fixed?
※ Parameter of "Evaporative Sensor" will be
fixed at -2°C(28.4°F), if there is any fault in Evaporative
Sensor.

Go to "Inspection" procedure.

The electrical systems are made up of many
harness and connectors. Many kinds of fault are caused by poor
connection of sensors and terminals. Thoroughly check connectors for
looseness, poor connection, bending, corrosion, contamination,
deterioration, or damage. Repair or replace as necessary and then go
to "Verification of Vehicle Repair"
procedure. |
| Terminal And Connector
Inspection |
| 1. |
Many malfunctions in the electrical system
are caused by poor harness and terminals.
Faults can also be caused by interference
from other electrical systems, and mechanical or chemical
damage. |
| 2. |
Thoroughly check connectors for looseness,
poor connection, bending, corrosion, contamination, deterioration,
or damage. |
| 3. |
Has a problem been found?

Repair as necessary and go to "Verification
of Vehicle Repair" procedure.

Go to "Signal Circuit Inspection"
procedure. |
| Signal Circuit
Inspection |
| 1. |
Check for open in harness.
| (2) |
Disconnect Evaporator Temp.
Sensor. |
| (3) |
Measure resistance between terminal
"1" of Evaporator Temp. Sensor and terminal "6" of Heater
& A/C controller.
Specification : Approx. 0
Ω
|

|
| (4) |
Is the measured resistance within
specifications?

Go to "Ground Circuit Inspection "
procedure.

Check for open in harness. Repair as
necessary and go to "Verification of Vehicle Repair"
procedure. | |
| Ground Circuit
Inspection |
| 1. |
Check for open in ground
harness.
| (2) |
Disconnect Evaporator Temp.
Sensor. |
| (3) |
Measure resistance between terminal
"2" of Evaporator Temp. Sensor and chassis
ground.
Specification : Approx. 0
Ω
|

|
| (4) |
Is the measured resistance within
specifications?

Go to "Component Inspection "
procedure.

Check for open in harness. Repair as
necessary and go to "Verification of Vehicle Repair"
procedure. | |
| 1. |
Check Evaporator Temp. Sensor.
| (2) |
Disconnect Evaporator Temp.
Sensor. |
| (3) |
Measure resistance between terminal
"1" and "2" of Evaporator Temp. Sensor.
Specification : Refer the
specifications in fig 3.
|


|
| (4) |
Is the measured resistance within
specifications in fig3? (tolerance limits ±3%)

Check Heater & A/C
controller.

Substitute with a known-good
Evaporator Temp. Sensor and check for proper
operation.
If the problem is corrected, replace
Evaporator Temp. Sensor and then go to "Verification of
Vehicle Repair"
procedure. | |
| 2. |
Check Heater & A/C
controller
| (2) |
Disconnect Evaporator Temp.
Sensor. |
| (3) |
Measure voltage between terminal "6"
of Heater & A/C controller and chassis
ground.
Specification : Approx.
5V
|

|
| (4) |
Is the measured voltage within
specifications?

Check connectors for looseness, poor
connection, bending, corrosion, contamination, deterioration,
or damage. Repair or replace as necessary and then go to
"Verification of Vehicle Repair" procedure.

Substitute with a known-good Heater
& A/C controller and check for proper
operation.
If the problem is corrected, replace
Heater & A/C controller and then go to "Verification of
Vehicle Repair"
procedure. | |
| Verification Of Vehicle
Repair |
After a repair, it is
essential to verify that the fault has been corrected.
| 1. |
Connect scantool and select "Diagnostic
Trouble Codes(DTCs)" mode and then clear
DTC. |
| 2. |
Operate the vehicle and monitor the DTC on
the scantool. |
| 3. |
Are any DTCs present?

Go to the applicable troubleshooting
procedure.

System is performing to specification at
this
time. |