Home › Emission Control System › Evaporative Emission Control System › Canister

Evaporative Emission Control System › Canister: Repair procedures

Removal
1.
Remove the fuel tank (Refer to "Fuel System" group).
2.
Disconnect hoses connecting to the canister (A).
3.
Unfasten two mounting bolts (B) and remove the canister (C).

Inspection
1.
Lock for loose connections, sharp bends or damage to the fuel vapor lines.
2.
Look for distortion, cranks or fuel damage.
3.
After removing the canister, inspect for cracks or damage.

Installation
Installation is in reverse order of removal.

Torque: 1.7 ~ 2.6 kgf.m (16.7 ~ 25.5 N.m, 12.3 ~ 18.8 lb-ft)

Purge Control Solenoid Valve (PCSV)
Inspection
When disconnecting the vacuum hose, make an identification mark on it so that it can be reconnected to its original position.
1.
Disconnect the vacuum hose from the solenoid valve.
2.
Detach the harness connector.
3.
Connect a vacuum pump to the intake manifold side of the PCSV.
4.
Apply vacuum and check when voltage and ground is applied to the PCSV and when the voltage and ground is disconnected.
Battery voltage
Normal condition
When applied
Vacuum is released
When disconnected
Vacuum is maintained

5.
Measure the resistance between the terminals of the solenoid valve when disconnected.

PCSV coil resistance(Ω) : 19.0 ~ 22.0Ω at 20°C (68°F)