| Function and operation
principle |
Heated Oxygen Sensor
(HO2S) consists of zirconium and alumina and is installed on upstream and
downstream of the Manifold Catalyst Converter (MCC). After it compares
oxygen consistency of the atmosphere with the exhaust gas, it communicates
the oxygen consistency of the exhaust gas to the ECM. The temperature of
the sensor's tip normally operates above 370°C (698°F). It uses a heater
which is controlled by the ECM duty signal. When the exhaust gas
temperature is lower than the specified value, the heater warms the sensor
tip.