The evaporative emission
control system prevents hydrocarbon vapors from escaping from the fuel
tank into the atmosphere where they could form photochemical smog.
Gasoline vapors are collected in the charcoal canister. The Fuel Tank
Pressure Sensor (FTPS) is installed on fuel pump assembly and is an
integral part of the evaporative monitoring system. The ECM monitors the
FTPS signal to detect vacuum decay and excess vacuum. The FTPS measures
the difference between the air pressure insidethe fuel tank and
atmospheric air pressure. The FTPS also checks the purge control solenoid
valve operation and leak detection in the evaporative emission control
system by monitoring pressure and vacuum levels in the fuel tank during
the purge control solenoid valve operating cycles.
|